active path for some LUNs; however, this configuration is not persistent across reboots. After a reboot, the
LUNs will be on a single HBA. The advantage of this configuration is it prevents unnecessary trespasses of
LUNs in the case of failure.
The failover time can be adjusted at the HBA, ESX, and virtual machine levels. The Fibre Channel SAN
Configuration Guide and iSCSI SAN Configuration Guide found on www.vmware.com
provide
recommendations for setting the failover time at the HBA and virtual machine level.
VMware ESX Server periodically evaluates the state of each path. The default evaluation period is 300
seconds. This can be changed by modifying the /proc/vmware/config/disk/PathEvalTime
vmkernel config value. This can also be done thru the MUI for ESX 2.x by going to Advanced Setting
and changing the Disk.PathEvalTime parameter. The evaluation period can be set to any value between 30
and 1500 seconds. Note that reducing the PathEvalTime causes path evaluation to run more frequently.
This puts a slightly higher CPU load on the system. Reducing this value (to 90 for example) will help
improve failover time (keeping in mind the preceding caveat).
Table 3 shows the failovermode policies supported for ESX 3.5 and ESX 4.0 with CLARiiON storage
systems.
Table 3. Failovermode policies
ESX
version
ALUA
PowerPath
(Failovermode = 4)
ALUA
Native
(Failovermode =4)
PNR mode
PowerPath
(Failovermode =1)
PNR mode
Native
(Failovermode =1)
ESX 4.0
Yes
(CX arrays running
FLARE 26 or later)
Yes
(Fixed or
Round Robin)
(CX4 arrays running
FLARE 28 version
04.28.000.5.704 or
later)
Yes
(CX arrays running
FLARE 22 or later)
Yes
(Round Robin or
MRU)
(CX arrays running
FLARE 22 or later)
ESX 3.5
No No No MRU
(CX arrays running
FLARE 22 or later)
LUN partitioning
LUNs presented to the ESX server are ultimately presented to the virtual machines. Any storage device
presented to any virtual machine is represented as a virtual disk. To the virtual machine, the virtual disk
appears to be a physical disk. A virtual machine can have multiple virtual disks of different/multiple virtual
disk types located on multiple SCSI controllers. A CLARiiON LUN presented to the ESX server can be
partitioned using one of the three methods:
Raw disks
VMFS volumes
Raw device mapping
EMC CLARiiON Integration with
VMware ESX Server
Applied Technology 24