Dell OpenManage Server Administrator Version 6.1 Guía de usuario Pagina 124

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 252
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 123
124 Storage Management Message Reference
2126 SCSI sense
sector
reassign
Warning /
Non-critical
Cause: A sector of the
physical disk is
corrupted and data
cannot be maintained
on this portion of the
disk. This alert is for
informational purposes.
CAUTION: Any
data residing on the
corrupt portion of the
disk may be lost and you
may need to restore your
data from backup.
Action: If the physical
disk is part of a non-
redundant virtual disk,
then back up the data
and replace the physical
disk.
CAUTION:
Removing a physical
disk that is included in a
non-redundant virtual
disk will cause the
virtual disk to fail and
may cause data loss.
If the disk is part of a
redundant virtual disk,
then any data residing
on the corrupt portion
of the disk will be
reallocated elsewhere in
the virtual disk.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
903
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
Vista de pagina 123
1 2 ... 119 120 121 122 123 124 125 126 127 128 129 ... 251 252

Comentarios a estos manuales

Sin comentarios