Dell OpenManage Server Administrator Version 6.1 Guía de usuario Pagina 156

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 252
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 155
156 Storage Management Message Reference
2202 A global hot
spare
has been
removed.
OK / Normal /
Informational
Cause: The controller is
unable to communicate
with a disk that is
assigned as a global hot
spare. The disk may
have been removed.
There may also be a bad
or loose cable.
Action: Check if the
disk is healthy and that
it has not been
removed. Check the
cables. If necessary,
replace the disk and
reassign the hot spare.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
901
2203 A dedicated
hot spare
failed.
Warning /
Non-critical
Cause: The controller is
unable to communicate
with a disk that is
assigned as a dedicated
hot spare. The disk may
have failed or been
removed. There may
also be a bad or loose
cable.
Action: Check if the
disk is healthy and that
it has not been
removed. Check the
cables. If necessary,
replace the disk and
reassign the hot spare.
Clear Alert
Number:
None.
Related Alert
Number: 2048
LRA Number:
2070
903
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
Vista de pagina 155