Dell OpenManage Server Administrator Version 6.1 Guía de usuario Pagina 63

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 252
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 62
System Event Log Messages for IPMI Systems 63
<Entity Name> PS
Redundancy
sensor redundancy
degraded.
Information Power supply redundancy
is degraded if one of the
power supply sources is
removed or failed.
<Entity Name> PS
Redundancy
sensor redundancy lost.
Critical Power supply redundancy is lost
if only one power supply is
functional.
<Entity Name> PS
Redundancy
sensor redundancy
regained.
Information This event is generated if the
power supply has been
reconnected or replaced.
<Power Supply Sensor
Name>
predictive failure
was asserted
Critical This event is generated when the
power supply is about to fail.
<Power Supply Sensor
Name>
input lost was
asserted
Critical This event is generated when the
power supply is unplugged.
<
Power Supply Sensor
Name
> predictive failure
was deasserted
Information This event is generated when the
power supply has recovered from
an earlier predictive failure event.
<
Power Supply Sensor
Name
> input lost was
deasserted
Information This event is generated when the
power supply is plugged in.
Table 3-5. Power Supply Events (continued)
Event Message Severity Cause
Vista de pagina 62
1 2 ... 58 59 60 61 62 63 64 65 66 67 68 ... 251 252

Comentarios a estos manuales

Sin comentarios