150 Storage Management Message Reference
2188 The
controller
write policy
has been
changed to
Write
Through.
OK / Normal /
Informational
Cause: The controller
battery is unable to
maintain cached data
for the required period
of time. For example, if
the required period of
time is 24 hours, the
battery is unable to
maintain cached data
for 24 hours. It is
normal to receive this
alert during the battery
Learn cycle as the Learn
cycle discharges the
battery before
recharging it. When
discharged, the battery
cannot maintain cached
data.
Action: Check the
health of the battery.
If the battery is weak,
replace the battery
pack.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
1151
2189 The
controller
write policy
has been
changed to
Write Back.
OK / Normal /
Informational
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
1151