Dell OpenManage Server Administrator Version 6.5 Guía de usuario Pagina 141

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 250
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 140
Storage Management Message Reference
141
2203 A dedicated
hot spare
failed.
Warning /
Non-critical
Cause:
The controller is
unable to communicate
with a disk that is
assigned as a dedicated
hot spare. The disk may
have failed or been
removed. There may
also be a bad or loose
cable.
Action:
Check if the
disk is healthy and that
it has not been
removed. Check the
cables. If necessary,
replace the disk and
reassign the hot spare.
Clear Alert:
None
Related Alert
Number:
2048
LRA Number:
2070
903
2204 A dedicated
hot spare has
been removed.
OK / Normal /
Informational
Cause:
The controller is
unable to communicate
with a disk that is
assigned as a dedicated
hot spare. The disk may
have been removed.
There may also be a bad
or loose cable.
Action:
Check if the
disk is healthy and that
it has not been
removed. Check the
cables. If necessary,
replace the disk and
reassign the hot spare.
Clear Alert:
None
Related Alert:
None
LRA Number:
None
901
Table 3-4. Storage Management Messages
(continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
Vista de pagina 140
1 2 ... 136 137 138 139 140 141 142 143 144 145 146 ... 249 250

Comentarios a estos manuales

Sin comentarios