Storage Management Message Reference
2306 Bad block table
is 80% full.
Warn ing /
Non-critical
Cause:
The bad block
table is used for
remapping bad disk
blocks. This table fills,
as bad disk blocks are
remapped. When the
table is full, bad disk
blocks can no longer be
remapped, and disk
errors can no longer be
corrected. At this point,
data loss can occur. The
bad block table is now
80% full.
Action:
Back up your
data. Replace the
disk generating this
alert and restore from
back up.
Clear Alert:
None
Related Alert
Number:
2307
LRA Number:
2070
903
Table 3-4. Storage Management Messages