System Event Log Messages for IPMI Systems
<Sensor Name/Location>
Fan sensor detected a
warning <Reading>.
Warning The speed of the specified <
Sensor
Name/Location
> fan may not be
sufficient to provide enough cooling
to the system.
<Sensor Name/Location>
Fan Redundancy sensor
redundancy degraded.
Information The fan specified by <
Sensor Name/
Location
> may have failed and hence,
the redundancy has been degraded.
<Sensor Name/Location>
Fan Redundancy sensor
redundancy lost.
Critical The fan specified by <
Sensor Name/
Location
> may have failed and hence,
the redundancy that was degraded
previously has been lost.
<Sensor Name/Location>
Fan Redundancy sensor
redundancy regained
Information The fan specified by <
Sensor Name/
Location
> may have started
functioning again and hence, the
redundancy has been regained.
Table 4-3. Fan Sensor Events
(continued)
Event Message Severity Cause