Storage Management Message Reference
2264 A device is
missing.
Warn ing /
Non-critical
Cause:
The controller
cannot communicate
with a device. The
device may be removed.
There may also be a bad
or loose cable.
Action:
Check if the
device is in and not
removed. If it is in,
check the cables. You
should also check the
connection to the
controller battery and
the battery health.
A battery with a weak or
depleted charge
may cause this alert.
Clear Alert:
None
Related Alert:
None
LRA Number:
2050, 2060,
2070, 2080,
2090, 2100
753
803
853
903
953
1003
1053
1103
1153
1203
Table 3-4. Storage Management Messages