Dell PowerVault DP500 Manual de usuario Pagina 7

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 86
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 6
E1610
PS # Missing
No power is available from the specified power supply;
specified power supply is improperly installed or faulty.
See Troubleshooting Power Supplies.
E1614
PS # Status
No power is available from the specified power supply;
specified power supply is improperly installed or faulty.
See Troubleshooting Power Supplies.
E1618
PS #
Predictive
Power supply voltage is out of acceptable range; specified
power supply is improperly installed or faulty.
See Troubleshooting Power Supplies.
E161C
PS # Input
Lost
Power source for specified power supply is unavailable, or
out of acceptable range.
Check the AC power source for the specified power supply. If problem
persists, see Troubleshooting Power Supplies.
E1620
PS # Input
Range
Power source for specified power supply is unavailable, or
out of acceptable range.
Check the AC power source for the specified power supply. If problem
persists, see Troubleshooting Power Supplies.
E1624
PS Redundancy
The power supply subsystem is no longer redundant. If the
last supply fails, the system will go down.
See Troubleshooting Power Supplies.
E1710
I/O Channel
Chk
The system BIOS has reported an I/O channel check.
See Getting Help.
E1711
PCI PERR B##
D## F##
PCI PERR Slot
#
The system BIOS has reported a PCI parity error on a
component that resides in PCI configuration space at bus
##, device ##, function ##.
The system BIOS has reported a PCI parity error on a
component that resides in the specified PCI slot.
Remove and reseat the PCI expansion cards. If the problem persists,
see Troubleshooting Expansion Cards.
Reinstall the expansion-card cage. See Expansion-Card Cage.
If the problem persists, the riser card or system board is faulty. See
Getting Help.
E1712
PCI SERR B##
D## F##
PCI SERR Slot
#
The system BIOS has reported a PCI system error on a
component that resides in PCI configuration space at bus
##, device ##, function ##.
The system BIOS has reported a PCI system error on a
component that resides in the specified slot.
Remove and reseat the PCI expansion cards. If the problem persists,
see Troubleshooting Expansion Cards.
Reinstall the expansion-card cage. See Expansion-Card Cage.
If the problem persists, the riser card or system board is faulty. See
Getting Help.
E1714
Unknown Err
The system BIOS has determined that there has been an
error in the system, but is unable to determine its origin.
See Getting Help.
E171F
PCIE Fatal
Err B## D##
F##
PCIE Fatal
Err Slot #
The system BIOS has reported a PCIe fatal error on a
component that resides in PCI configuration space at bus
##, device ##, function ##.
The system BIOS has reported a PCIe fatal error on a
component that resides in the specified slot.
Remove and reseat the PCI expansion cards. If the problem persists,
see Troubleshooting Expansion Cards.
Reinstall the expansion-card cage. See Expansion-Card Cage.
If the problem persists, the riser card or system board is faulty. See
Getting Help.
E1810
HDD ## Fault
The SAS subsystem has determined that hard drive ## has
experienced a fault.
See Troubleshooting a Hard Drive.
E1811
HDD ## Rbld
Abrt
The specified hard drive has experienced a rebuild abort.
See Troubleshooting a Hard Drive. If the problem persists, see your
RAID documentation.
E1812
HDD ##
Removed
The specified hard drive has been removed from the system.
Information only.
E1913
CPU &
Firmware
Mismatch
The BMC firmware does not support the CPU.
Update to the latest BMC firmware. See the BMC User's Guide for more
information on setup and use of BMC.
E1A11
PCI Rsr
Config
PCI risers are not configured correctly; some invalid
configurations may prevent the system from powering on.
See Expansion-Card Riser Boards.
E1A12
PCI Rsr
Missing
One or all of the PCI risers is missing, preventing the system
from powering on.
Information only.
E1A14
SAS Cable A
SAS cable A is missing or bad.
Reseat the cable. If problem persists, replace cable. See SAS Controller
Daughter Card.
E1A15
SAS Cable B
SAS cable B is missing or bad.
Reseat the cable. If problem persists, replace cable. See SAS Controller
Daughter Card.
E2010
No Memory
No memory is installed in the system.
Install memory. See Installing Memory Modules.
E2011
Mem Config
Err
Memory detected, but is not configurable. Error detected
during memory configuration.
See Troubleshooting System Memory.
E2012
Unusable
Memory
Memory is configured, but not usable. Memory subsystem
failure.
See Troubleshooting System Memory.
E2013
Shadow BIOS
Fail
The system BIOS failed to copy its flash image into memory.
See Troubleshooting System Memory.
E2014
CMOS Fail
CMOS failure. CMOS RAM not functioning properly.
See Getting Help.
E2015
DMA
Controller
DMA controller failure.
See Getting Help.
E2016
Int
Controller
Interrupt controller failure.
See Getting Help.
E2017
Timer Fail
Timer refresh failure.
See Getting Help.
E2018
Prog Timer
Programmable interval timer error.
See Getting Help.
E2019
Parity Error
Parity error.
See Getting Help.
E201A
SIO Err
SIO failure.
See Getting Help.
E201B
Kybd
Controller
Keyboard controller failure.
See Getting Help.
Vista de pagina 6
1 2 3 4 5 6 7 8 9 10 11 12 ... 85 86

Comentarios a estos manuales

Sin comentarios