Dell PowerVault NX1950 Manual de usuario Pagina 59

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 70
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 58
Appendix 59
If multiple-paths to the Target are available, then you must describe each
path to the iSCSI Initiator. To describe multiple paths to the Initiator:
1
In the
Log On
window, select
Enable multi-path
and select
Advanced
.
The
Advanced
option provides a drop-down menu with all possible source
(Initiator) IP addresses and a separate drop-down menu for all possible
Target portal addresses. In this scenario, the Target solution manages the
actual paths and IP addresses internally. Other Target solutions display
each available IP address that can be used for multi-path operations.
2
Select each desired combination of source IP address and Target IP address
and login separately to have multiple sessions for the same Target device.
3
Select
Automatically restore this connection when the system boots
to
ensure continuous connection and to avoid establishment of
Target-Initiator association during power spike or system reboots.
4
Repeat the
Log on
process for each iSCSI NIC.
Figure A-4. Log On to Target Window
For MPIO connection, you must select the Target that displays status as
Connected and select Log On. In the Log On to Target window, select
Advanced and configure redundant iSCSI Target IP address.
NOTE: MPIO connections are not supported with the PowerVault NX1950 cluster
solution configured with 3.0 iSCSI Target. MPIO connections are supported with
PowerVault NX1950 cluster solution configured with 3.1 iSCSI Target and Microsoft
iSCSI Initiator version 2.06 or later.
Vista de pagina 58
1 2 ... 54 55 56 57 58 59 60 61 62 63 64 ... 69 70

Comentarios a estos manuales

Sin comentarios