Electrical indicator
Condition Corrective Action
The indicator blinks amber if the system
experiences an electrical error (for
example, voltage out of range, or a failed
power supply or voltage regulator).
See the System Event Log or system messages for the specific
issue. If it is due to a problem with the power supply, check the
LED on the power supply. Re-seat the power supply by removing
and reinstalling it. If the problem persists, see Getting Help.
Temperature indicator
Condition Corrective Action
The indicator blinks amber if the
system experiences a thermal error
(for example, a temperature out of
range or fan failure).
Ensure that none of the following conditions exist:
A cooling fan is removed or has failed.
System cover, cooling shroud, EMI filler panel, memory-
module blank, or back-filler bracket is removed.
Ambient temperature is too high.
External airflow is obstructed.
See Getting Help.
Memory indicator
Condition Corrective Action
The indicator blinks amber if a
memory error occurs.
See the system event log or system messages for the location of the failed
memory. Reinstall the memory device. If the problem persists, see Getting
Help.
PCIe indicator
Condition Corrective Action
The indicator blinks amber if a PCIe card
experiences an error.
Restart the system. Update any required drivers for the PCIe card.
Re-install the card. If the problem persists, see Getting Help.