Configuring a Redundant System
BIG-IP® Reference Guide 6-15
To synchronize the configuration using the Configuration
utility
1. In the navigation pane, click System.
The Network Map screen opens.
2. Click the Redundant Properties tab.
The Redundant Properties screen opens.
3. Click the Synchronize Configuration button.
To synchronize the configuration from the command line
To synchronize the configuration between two BIG-IP units from the
command line, use the following command:
b config sync all
Task 8: Transitioning from active/standby to active-active
To transition from active/standby to active-active, type the following
command on the active BIG-IP:
b failover standby
This command puts the active BIG-IP into partial active-active mode. To
complete the transition, type in the following command on the other BIG-IP
which now considers itself the active unit.
b failover standby
Now both units are in active-active mode.
Note
This task is not required if you enable active-active in the Configuration
utility. The transition is made during Task 1: Enabling active-active on the
BIG-IP, on page 6-11.
Understanding active-active system fail-over
Before a failure in an active-active installation, one BIG-IP is servicing all
requests for virtual servers configured on unit 1, and the other BIG-IP is
servicing all requests for virtual servers configured on unit 2. If one of the
BIG-IP units fails, the remaining BIG-IP handles all requests for virtual
servers configured to run on unit 1 and also those configured to run on
unit 2. In other words, the surviving BIG-IP is acting as both units 1 and 2.
If the BIG-IP that failed reboots, it re-assumes connections for the unit
number with which it was configured. The BIG-IP that was running as both
units stops accepting connections for the unit number that has resumed
service. Both machines are now active.
When the unit that was running both unit numbers surrenders a unit number
to the rebooted machine, all connections are lost that are now supposed to
run on the rebooted machine, unless they were mirrored connections.