Dell PowerEdge 1800 Guía para resolver problemas Pagina 19

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 160
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 18
Indicators, Codes, and Messages 19
Figure 2-7. SCSI Hard-Drive Indicators
Table 2-6 lists the drive status indicator codes. Different codes display as drive events occur in the
system. For example, in the event of a hard-drive failure, the "drive fail" code appears. After the
drive is selected for removal, the "preparing for removal" code appears. After the replacement drive
is installed, the "preparing for operation, drive online" code appears.
The drive-busy indicator signifies whether the hard drive is active on the SCSI bus. The indicator is
controlled by the hard drive.
Table 2-6. SCSI Hard-Drive Status Indicator Codes
Drive-Status Indicator Indicator Code
Drive bay empty Off
Drive being prepared for operation,
drive online
Steady green
Drive being identified or prepared for
removal
Blinks green three times per second at equal intervals
Drive rebuilding Blinks green once per second
Drive offline or failed Steady amber
Vista de pagina 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 159 160

Comentarios a estos manuales

Sin comentarios