E07F1
TEMP CPU n
HOT
Specified microprocessor is out of acceptable
temperature range and has halted operation.
See "Troubleshooting System Cooling Problems" in "Troubleshooting Your
System." If the problem persists, ensure that the microprocessor heat sinks
are properly installed (see "Replacing a Processor" in "Installing System
Components").
E07F4
POST CACHE
Faulty or improperly installed microprocessor.
See "Troubleshooting the Microprocessors" in "Troubleshooting Your System."
E07F4
POST CPU REG
E07F4
POST CPU SMI
SMI handler failed to initialize; faulty system
board.
See "Getting Help."
E07FA
TEMP CPU n
THERM
Specified microprocessor is out of acceptable
temperature range and is operating at a reduced
speed, or frequency.
See "Troubleshooting System Cooling Problems" in "Troubleshooting Your
System." If the problem persists, ensure that the microprocessor heat sinks
are properly installed (see "Replacing a Processor" in "Installing System
Components").
E0876
POWER PS n
No power available from the specified power
supply; specified power supply is improperly
installed or faulty.
See "Troubleshooting Redundant Power Supplies" in "Troubleshooting Your
System."
E0880
INSUFFICIENT
PS
Insufficient power is being supplied to the
system; power supplies are improperly installed,
faulty, or missing.
See "Troubleshooting Redundant Power Supplies" in "Troubleshooting Your
System."
E0CB2
MEM SPARE ROW
Correctable errors threshold was met in a
memory bank: errors were remapped to the
spare row.
See "Troubleshooting System Memory" in "Troubleshooting Your System."
E0CF1
MBE DIMM Bank
n
Memory modules installed in the specified bank
are not the same type and size; faulty memory
module(s).
Ensure that both memory modules in the bank are the same type and size
and that they are properly installed. If the problem persists, see
"Troubleshooting System Memory" in "Troubleshooting Your System."
E0CF1
POST MEM 64K
Parityfailureinthefirst64KBofmainmemory.
See "Troubleshooting System Memory" in "Troubleshooting Your System."
E0CF1
POST NO
MEMORY
Main-memory refresh verification failure.
See "Troubleshooting System Memory" in "Troubleshooting Your System."
E0CF5
LOG DISABLE
SBE
Multiple single-bit errors on a single memory
module.
See "Troubleshooting System Memory" in "Troubleshooting Your System."
E0D76
BP DRIVE FAIL
n
1x2 DRIVE
FAIL n
Faulty or improperly installed hard drive or RAID
controller.
See "Troubleshooting SCSI Hard Drives" "Troubleshooting a RAID Controller
Card, " and "Troubleshooting the Integrated RAID Controller" in
"Troubleshooting Your System."
E0F04
POST CMOS
CMOS write/read failure; faulty system board.
See "Getting Help."
E0F04
POST CPU
SPEED
Microprocessor speed control sequence failure.
See "Getting Help."
E0F04
POST DMA INIT
DMA initialization failure; DMA page register
write/read failure.
See "Troubleshooting System Memory" in "Troubleshooting Your System."
E0F04
POST DMA REG
Faulty system board.
See "Getting Help."
E0F04
POST KYB
CNTRL
Faulty keyboard controller; faulty system board.
See "Getting Help."
E0F04
POST MEM RFSH
Main-memory refresh verification failure.
See "Troubleshooting System Memory" in "Troubleshooting Your System."
E0F04
POST PIC REG
Master or slave PIC register test failure.
See "Getting Help."
E0F04
POST SHADOW
BIOS-shadowing failure.
See "Troubleshooting System Memory" in "Troubleshooting Your System."
E0F04
POST SHD TEST
Shutdown test failure.
E0F04
POST SIO
Super I/O chip failure; faulty system board.
See "Getting Help."
E0F04
POST TIMER
Programmable interval timer test failure; faulty
system board.
See "Getting Help."
E0F0B
POST ROM
CHKSUM
Faulty or improperly installed expansion card.
See "Troubleshooting Expansion Cards" in "Troubleshooting Your System."
E0F0C
VID MATCH CPU
n
Specified microprocessor is faulty, unsupported,
improperly installed, or missing.
See "Troubleshooting the Microprocessors" in "Troubleshooting Your System."
E10F3
LOG DISABLE
BIOS
BIOS disabled logging errors.
Check the SEL for details on the errors.
E13F2
IO CHANNEL
CHECK
Faulty or improperly installed expansion card;
faulty system board.
See "Troubleshooting Expansion Cards" in "Troubleshooting Your System."
E13F4
PCI PARITY
E13F5
PCI SYSTEM
E13F8
CPU BUS INIT
Faulty or improperly installed microprocessor or
system board.
See "Troubleshooting the Microprocessors" in "Troubleshooting Your System."
If the problem persists, see "Getting Help."
E13F8
CPU BUS
PARITY
Faulty system board.
See "Getting Help."
E13F8
CPU MCKERR
Machine check error; faulty or improperly installed
microprocessor; faulty system board.
See "Troubleshooting the Microprocessors" in "Troubleshooting Your System."
E13F8
HOST BUS
Faulty system board.
See "Getting Help."
E13F8
HOST TO PCI
BUS
E13F8
MEM
CONTROLLER
Faulty or improperly installed memory module;
faulty system board.
See "Troubleshooting System Memory" in "Troubleshooting Your System."
E1580
POWER CONTROL
Faulty system board.
See "Getting Help."