Dell PowerEdge 800 Guía para resolver problemas Pagina 70

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 82
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 69
11. Connect the power cable connector P3 to the power connector on the SCSI backplane. See Figure7-13.
12. Connect the baseboard management controller (BMC) inter-IC (I2C) cable to the SCSI backplane. See Figure7-13.
13. Connect the other end of the BMC I2C cable to connector BP_I2C on the system board. See FigureA-3.
14. Install the SCSI controller card.
See "Installing an Expansion Card" in "Installing System Components" for instructions about installing the card.
15. Connect the SCSI data cable to the SCSI controller card, and to the SCSI interface connector on the backplane. See Figure7-12 and Figure7-13.
16. Install the cover. See "Replacing the Cover" in "Troubleshooting Your System."
17. Stand the system upright.
18. Install the SCSI drives into the hard-drive bay.
See Figure7-11.
19. Install the bezel. See "Installing the Bezel" in "Troubleshooting Your System."
20. Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
21. Install any required SCSI device drivers.
22. Run the SCSI controllers tests and the hard-drive tests in the system diagnostics. See "Running the System Diagnostics."
Installing a RAID Controller Card
See "Installing an Expansion Card" in "Installing System Components" for instructions about installing the card.