Dell OpenManage Server Administrator Version 5.5 Guía de usuario Pagina 108

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 238
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 107
108 Storage Management Message Reference
2106 Smart FPT
exceeded
Warning /
Non-
critical
Cause: A disk on the
specified controller has
received a SMART alert
(predictive failure)
indicating that the disk is
likely to fail in the near
future.
Action: Replace the disk
that has received the
SMART alert. If the
physical disk is a member
of a non-redundant virtual
disk, then back up the data
before replacing the disk.
NOTICE: Removing
a physical disk that
is included in a
non-redundant virtual
disk will cause the
virtual disk to fail and
may cause data loss.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2070
903
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
Vista de pagina 107
1 2 ... 103 104 105 106 107 108 109 110 111 112 113 ... 237 238

Comentarios a estos manuales