Storage Management Message Reference 165
2246 The
controller
battery is
degraded.
Warning /
Non-
critical
Cause: The controller
battery charge is weak.
Action: As the charge
weakens, the charger
should automatically
recharge the battery. If the
battery has reached its
recharge limit, replace the
battery pack. Monitor the
battery to make sure that it
recharges successfully.
If the battery does not
recharge, replace the
battery pack.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2100
1153
2247 The
controller
battery is
charging.
OK /
Normal
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Number: 2358.
Related Alert
Number:
None.
LRA Number:
None.
1151
2248 The
controller
battery is
executing a
Learn cycle.
OK /
Normal
Cause: This alert is for
informational purposes.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
1151
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
Vista de pagina 164