Storage Management Message Reference 133
2159 Virtual disk
renamed
OK /
Normal
Cause: This alert is for
informational purposes. A
user has renamed a virtual
disk.
When renaming a virtual
disk on a PERC 3/SC, 3/
DCL, 3/DC, 3/QC, 4/SC,
4/DC, 4e/DC, 4/Di, CERC
ATA100/4ch, PERC 5/E,
PERC 5/i or SAS 5/iR
controller, this alert
displays the new virtual
disk name.
On the PERC 3/SC, 3/
DCL, 3/DC, 3/QC, 4/SC,
4/DC, 4e/DC, 4/Di, 4/IM,
4e/Si, 4e/Di, and
CERC ATA 100/4ch
controllers, this alert
displays the original virtual
disk name.
Action: None
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
1201
2162 Communica
tion
regained
OK /
Normal
Cause: This alert is for
informational purposes.
Communication with an
enclosure has been
restored.
Action: None
Clear Alert
Status: Alert
2162 is a clear
alert for alerts
2137 and 2292.
Related Alert
Number:
None.
LRA Number:
None.