Storage Management Message Reference 151
2201 A global hot
spare failed.
Warning /
Non-
critical
Cause: The controller is
not able to communicate
with a disk that is assigned
as a dedicated hot spare.
The disk may have been
removed. There may also
be a bad or loose cable.
Action: Check if the disk is
healthy and that it has not
been removed. Check the
cables. If necessary, replace
the disk and reassign the
hot spare.
Clear Alert
Number:
None.
Related Alert
Number: 2048
LRA Number:
2070
903
2202 A global hot
spare
has been
removed.
OK /
Normal
Cause: The controller is
unable to communicate
with a disk that is assigned
as a global hot spare. The
disk may have been
removed. There may also
be a bad or loose cable.
Action: Check if the disk is
healthy and that it has not
been removed. Check the
cables. If necessary, replace
the disk and reassign the
hot spare.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
None.
901
Table 4-4. Storage Management Messages (continued)