Vista de pagina 152
Storage Management Message Reference 153
2206 The only hot
spare
available is a
SATA disk.
SATA disks
cannot
replace
SAS disks.
Warning /
Non-
critical
Cause: The only physical
disk available to be assigned
as a hot spare is using
SATA technology. The
physical disks in the virtual
disk are using SAS
technology. Because of this
difference in technology,
the hot spare cannot
rebuild data if one of the
physical disks in the virtual
disk fails.
Action: Add a SAS disk
that is large enough to be
used as the hot spare and
assign the new disk as a hot
spare.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2070
903
2207 The only hot
spare
available is a
SAS disk.
SAS disks
cannot
replace
SATA disks.
Warning /
Non-
critical
Cause: The only physical
disk available to be assigned
as a hot spare is using SAS
technology. The physical
disks in the virtual disk are
using SATA technology.
Because of this difference
in technology, the hot spare
cannot rebuild data if one
of the physical disks in the
virtual disk fails.
Action: Add a SATA disk
that is large enough to be
used as the hot spare and
assign the new disk as a hot
spare.
Clear Alert
Number:
None.
Related Alert
Number:
None.
LRA Number:
2070
903
Table 4-4. Storage Management Messages (continued)
Event
ID
Description Severity Cause and Action Related Alert
Information
SNMP
Trap
Numbers
Vista de pagina 152