About Your Solution 23
Table 1-3. LCD Status Messages
Code Text Causes Corrective Actions
E1000 Failsafe
voltage error.
Contact
support.
Check the system event
log for critical failure
events.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 113.
E1114 Ambient Temp
exceeds
allowed range.
Ambient temperature has
reached a point outside of
the allowed range.
See "Troubleshooting
System Cooling
Problems" on page 96.
E1116 Memory
disabled, temp
above range.
Power cycle
AC.
Memory has exceeded
allowable temperature and
has been disabled to
prevent damage to the
components.
Remove AC power to the
system for 10 seconds and
restart the system.
See "Troubleshooting
System Cooling
Problems" on page 96.
If the problem persists,
see "Getting Help" on
page 113.
E1210 Motherboard
battery
failure. Check
battery.
CMOS battery is missing
or the voltage is outside of
the allowable range.
See "Troubleshooting the
System Battery" on
page 95.
E1211 RAID
Controller
battery
failure. Check
battery.
RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.
Reseat the RAID battery
connector. See
"Troubleshooting System
Cooling Problems" on
page 96.
E1216 3.3V Regulator
failure.
Reseat PCIe
cards.
3.3 V voltage regulator has
failed.
Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting an
Expansion Card" on
page 101.