24 About Your Solution
E1229 CPU # VCORE
Regulator
failure.
Reseat CPU.
Specified processor
VCORE voltage regulator
has failed.
Reseat the processor. See
"Troubleshooting the
Processor" on page 102.
If the problem persists,
see "Getting Help" on
page 113.
E122A CPU # VTT
Regulator
failure.
Reseat CPU.
Specified processor VTT
voltage regulator has
failed.
Reseat the processor. See
"Troubleshooting the
Processor" on page 102.
If the problem persists,
see "Getting Help" on
page 113.
E122C CPU Power
Fault. Power
cycle AC.
A power fault was
detected when powering
up the processor.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 113.
E122D Memory
Regulator #
Failed. Reseat
DIMMs.
One of the memory
regulators has failed.
Reseat the memory
modules. See
"Troubleshooting System
Memory" on page 97.
E122E On-board
regulator
failed. Call
support.
One of the on-board
voltage regulators failed.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 113.
E1310 Fan ## RPM
exceeding
range. Check
fan.
RPM of specified fan is
outside of the intended
operating range.
See "Troubleshooting
System Cooling
Problems" on page 96.
Table 1-3. LCD Status Messages
(continued)
Code Text Causes Corrective Actions
book.book Page 24 Monday, January 24, 2011 12:24 PM