Dell PowerVault NX3500 Manual de usuario Pagina 42

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 118
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 41
42 About Your Solution
Sector not found.
Seek error.
Seek operation
failed.
Faulty hard drive. Replace the hard drive.
Ensure that the SAS
backplane cables are properly
connected. See
"Troubleshooting a Hard
Drive" on page 100 for the
appropriate drive(s) installed
in your system.
Shutdown
failure.
General system error. See "Getting Help" on
page 113.
The amount of
system memory has
changed.
Memory has been added or
removed or a memory
module may be faulty.
If memory has been added or
removed, this message is
informative and can be
ignored. If memory has not
been added or removed,
check the SEL to determine
if single-bit or multi-bit
errors were detected and
replace the faulty memory
module.
See "Troubleshooting
System Memory" on page 97.
Table 1-4. System Messages
(continued)
Message Causes Corrective Actions
book.book Page 42 Monday, January 24, 2011 12:24 PM
Vista de pagina 41
1 2 ... 37 38 39 40 41 42 43 44 45 46 47 ... 117 118

Comentarios a estos manuales

Sin comentarios