42 About Your Solution
Sector not found.
Seek error.
Seek operation
failed.
Faulty hard drive. Replace the hard drive.
Ensure that the SAS
backplane cables are properly
connected. See
"Troubleshooting a Hard
Drive" on page 100 for the
appropriate drive(s) installed
in your system.
Shutdown
failure.
General system error. See "Getting Help" on
page 113.
The amount of
system memory has
changed.
Memory has been added or
removed or a memory
module may be faulty.
If memory has been added or
removed, this message is
informative and can be
ignored. If memory has not
been added or removed,
check the SEL to determine
if single-bit or multi-bit
errors were detected and
replace the faulty memory
module.
See "Troubleshooting
System Memory" on page 97.
Table 1-4. System Messages
(continued)
Message Causes Corrective Actions