20
Fixed problems
EMC AX4-5 Series Integrated Management Software Release Notes
Platforms Brief description Symptom details
Solution (or
workaround)
AX4-5
AX4-5i
AX4-5SC
AX4-5SCi
FLARE Operating
Environment
Making a LUN snapshot
available to a host system while
there is a LUN migration in
process on the storage system
may result in storage processor
bugchecks (0xe117b264).
21208350/191115
Frequency of occurrence
:
Always under a rare set of
circumstances
Severity
:
Medium
Making a LUN snapshot
available to a host system
(using the host-based
admsnap activate
command) while there is a
LUN migration in process
on the storage system will
result in a single bugcheck
(0xe117b264) on the
storage processor that
owns the LUN being
migrated. If the LUN has
auto-assignment enabled,
the peer storage processor
may reboot with the same
bugcheck.
KnowledgeBase ID
:
None
Fixed in code
Exists in versions
:
02.23.050.5.004
02.23.050.5.504
02.23.050.5.505
02.23.050.5.703
Fixed in version
:
02.23.050.5.705
AX4-5
AX4-5i
AX4-5SC
AX4-5SCi
FLARE Operating
Environment
When several fabric state
changes occur very closely
together, one of various single
storage processor bugchecks
may occur.
26244824/211800
Frequency of occurrence
:
Likely under a rare set of
circumstances.
Severity
:
Medium
When several fabric state
changes occur very closely
together, one of various
single storage processor
bugchecks (including but
not limited to 0x000000c2,
0x000000c5, or
0x00000044) may occur.
KnowledgeBase ID
:
None
Fixed in code
Exists in versions
:
02.23.050.5.004
02.23.050.5.504
02.23.050.5.505
02.23.050.5.703
Fixed in version
:
02.23.050.5.705
AX4-5
AX4-5i
AX4-5SC
AX4-5SCi
FLARE Operating
Environment
Single or multiple SATA drives
may drop out when an
enclosure experiences a power
cycle or glitch.
202516, 201305
Frequency of occurrence
:
High under a specific set of
circumstances
Severity:
Medium
During I/O load, single or
multiple drives may drop
out when an enclosure has
a power cycle or glitch
because the SAS
controller may fail to
properly initialize a SATA
drive in a SAS topology.
KnowledgeBase ID
:
None
Fixed in code
Exists in version:
02.23.050.5.703
Fixed in version
:
02.23.050.5.705