EMC AX4-5 Series Integrated Management Software Release Notes
Technical notes
This section contains information that will help with the installation, use,
and management of the storage system. It provides generic information
that applies to all platforms, as well as platform-specific information.
Navisphere CLI
Navisphere CLI is no longer supported on the AX4-5 series storage
systems. Navisphere Secure CLI should be used instead.
Background verify
To improve system performance, the default rate for background verify
operations has been changed from ASAP to Medium. For systems
running 02.23.050.5.004 which are upgraded to 02.23.050.5.504 or
02.23.050.5.7xx, the rate will remain at Medium unless manually changed
using Navisphere Manager (requires full Navisphere Manager to be
installed).
Single-SP configuration
The proper configuration for single-SP systems has the SP installed in the
SP A slot of the DPE. A single-SP storage system with the SP installed in
the B slot causes continuous reboot of the SP.
Single-SP to dual-SP upgrades
1. Install the Dual-SP enabler using Navisphere Express and wait for
installation to complete. Verify using NaviSecCli ndu -status.
2. Destroy domain and security information using the Setup page
option.
3. Install SP B (with the storage system powered up).
4. Wait for SP B to boot and stabilize. The SP fault LED will become
solid green.
5. Use the Navisphere Initialization Tool UI to discover the storage
system. Repeat until both SPs are displayed when next is clicked.
6. Use the Initialization Tool UI to set up the storage system.
7. Wait for both SPs to reboot (to pick up new IP information)