26
Fixed problems
EMC AX4-5 Series Integrated Management Software Release Notes
Platforms Brief description Symptom details
Solution (or
workaround)
AX4-5
AX4-5i
AX4-5SC
AX4-5SCi
Navisphere Express
A Solaris PowerPath device is
displayed in Navisphere
Express with the native device
name.
182773
Frequency of occurrence
:
Always under a specific set of
circumstances.
Severity
:
Medium
The PowerPath device
name is not displayed until
the device is mounted on
Solaris. This happens only
in the user interface; The
Naviserverutilcli displays
the device name properly.
The PowerPath device
name is now properly
displayed in
Navisphere Express.
Exists in version
:
02.23.050.5.504
Fixed in version
:
02.23.050.5.703
Problems fixed in version 02.23.050.5.505
Platforms Brief description Symptom details
Solution (or
workaround)
AX4-5i
AX4-5SCi
FLARE Operating
Environment
An AX4-5 iSCSI storage system
may experience SP reboots
when running multi-threaded
large block read I/O.
195543
Frequency of occurrence
:
Likely under a specific set of
circumstances.
Severity
:
Critical
An AX4-5 iSCSI storage
system may experience
SP reboots when running
multi-threaded large block
read I/O. The unique
signature “-R- Data Buffer
RAM Parity Error Bus” can
be found in the navi_getlog
file in SPcollects. The
problem can be seen
within 15-20 minutes of
starting the I/O load, but
there is considerable
variation.
Knowledgebase solution
:
emc184908
Fixed in code
Exists in versions
:
02.23.050.5.004
02.23.050.5.504
Fixed in version:
02.23.050.5.505
Vista de pagina 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 46 47

Comentarios a estos manuales

Sin comentarios