142 omconfig: Managing Components Using the Instrumentation Service
config=serial baudrate=9600 | 19200 |
38400 | 57600 | 115200
9600: Sets the connection speed to 9600
bits per second.
19200: Sets the connection speed to
19200 bits per second.
38400: Sets the volatile and non-volatile
connection speed to 38400 bits per
second.
57600: Sets the volatile and non-volatile
connection speed to 57600 bits per
second.
115200: Sets the volatile and non-
volatile connection speed to 115200 bits
per second.
NOTE: Baud rates of 9600 and 19200 are
supported on PowerEdge 1800, 1850, 2800,
and 2850 systems.
NOTE: Baud rates of 19200, 38400, and
57600 are supported on PowerEdge
x
9
xx
systems.
NOTE: Baud rate of 115200 is supported
on certain systems that have a DRAC 5
installed.
NOTE: Baud rate of 19200, 57600, and
115200 are supported on
yx0x
systems that
have iDRAC installed.
flowcontrol=none | rtscts none: No control over the flow of
communication through the serial port.
rtscts: RTS is ready to send and CTS is
clear to send.
Table 4-12. Parameters of omconfig chassis remoteaccess or omconfig mainsystem
remoteaccess
(continued)
name=value pair 1
config=
name=value pair 2 Description