Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Manual de usuario Pagina 162

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 316
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 161
162 omconfig: Managing Components Using the Instrumentation Service
Example Set Alert Action Commands
The following examples are valid example commands. For each successful
command issued, the following message is displayed:
Alert action(s) configured successfully.
For Current Probe Actions
To disable system console alert if a current probe detects a warning event,
type:
omconfig system alertaction event=currentwarn
alert=false
or
omconfig servermodule alertaction event=
currentwarn alert=false
To enable broadcast messages if a current probe detects a failure event, type:
omconfig system alertaction event=currentfail
broadcast=true
or
omconfig servermodule alertaction event=
currentfail broadcast=true
For Fan Probe Actions
To generate alerts when a fan probe detects a failure value, type:
omconfig system alertaction event=fanfail alert=
true
or
omconfig servermodule alertaction event=fanfail
alert=true
event=storagectrlbatteryfail Sets actions when a storage controller battery detects a
failure value.
NOTE: This event is not available on Blade systems.
Table 4-23. Events for Which You Can Set Alert Actions
(continued)
Event Name Description
Vista de pagina 161
1 2 ... 157 158 159 160 161 162 163 164 165 166 167 ... 315 316

Comentarios a estos manuales

Sin comentarios