Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS Manual de usuario Pagina 208

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 316
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 207
208 omreport storage Commands
omreport Fan Status
Table 7-7 describes the syntax for the omreport fan commands.
Table 7-7. omreport Fan Status Commands
Required Command Levels
(1, 2, 3) and name=value pair
Optional name=value pairs Use
omreport storage
enclosure
Displays property
information for all
enclosures attached to the
system.
controller=id enclosure=
<ENCLOSUREID>
info=fans
where id is the controller number
and ENCLOSUREID is the
enclosure number.
For example: controller=0
enclosure=2
NOTE: For SCSI controllers, the
ID specified in enclosure=
<ENCLOSUREID> is the connector
number and for Serial Attached
SCSI (SAS) controllers, ID is the
connectorNumber:EnclosureIndex.
Displays the information
about the fans for the
specific enclosure.
controller=id enclosure=
<ENCLOSUREID>
info=fans index=n
where id is the controller number
and ENCLOSUREID is the
enclosure number and “n” is the
number of a fan.
For example: controller=0
enclosure=2 info=fans index=1
Displays the specified
fan.
Vista de pagina 207
1 2 ... 203 204 205 206 207 208 209 210 211 212 213 ... 315 316

Comentarios a estos manuales

Sin comentarios