88 omreport: Viewing System Status Using the Instrumentation Service
Network Data
The following details are listed for each NIC and Team interface, if Team
interface is configured in the system:
•IP Address
•Subnet Mask
•Default Gateway
•MAC Address
Storage Enclosures
The following details are listed for each storage enclosure attached to the
system:
•Name
•Service Tag
omreport system thrmshutdown or omreport servermodule
thrmshutdown
Use the omreport system thrmshutdown or omreport servermodule
thrmshutdown command to view the properties configured for a thermal
shutdown action.
The three properties that display for thermal shutdown are disabled, warning,
or failure. If the CLI displays the following message, the thermal shutdown
feature has been disabled:
Thermal protect shutdown severity: disabled
If the system is configured to shutdown when a temperature probe detects
a warning or failure event, one of the following messages is displayed:
Thermal protect shutdown severity: warning
Thermal protect shutdown severity: failure
omreport system version or omreport servermodule version
Use the omreport system version or omreport servermodule version
command to list the version numbers of the BIOS, firmware, systems
management software, and operating system installed on the system.