omreport: Viewing System Status Using the Instrumentation Service 75
The following is an example output for a few components:
Current SNMP Trap Configuration
-----------
System
-----------
Settings
Enable: Informational, Warning and Critical
Disable: None
---------------
Power Supplies
----------------
Settings
Enable: Informational, Warning and Critical
Disable: None
-----------
Fans
-----------
Settings
Enable: Critical
Disable: Informational, Warning, and Critical
---------------------
Removable Flash Media
---------------------
Settings
Enable: Informational, Warning and Critical
Disable: None
The full report lists the settings for all components in the system for which
events are generated.
To view the status for components of a specific type, use the omreport system
events type=<component name> or omreport servermodule event type=
<
component name
>
command. This command displays a summary of each
component in the system for which events are generated. Table 3-7 lists the
events displayed for various component types.
NOTE: Due to the limitations of certain operating systems (for example, VMware
ESXi), certain features are not available with this release of OpenManage Server
Administrator.