Dell Chassis Management Controller Version 4.50 Manual de usuario Pagina 215

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 260
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 214
where <
value
> is a number between 2715–16685 representing the maximum power limit in Watts. The default is
16685.
For example, the following command sets the System Input Power Cap to 5400 watts:
racadm config -g cfgChassisPower -o cfgChassisPowerCap 5400
.
To enable or disable dynamic PSU engagement, type:
racadm config -g cfgChassisPower -o cfgChassisDynamicPSUEngagementEnable
<value>
where <
value
> is 0 (disable), 1 (enable). The default is 0.
For example, the following command disables dynamic PSU engagement:
racadm config -g cfgChassisPower -o cfgChassisDynamicPSUEngagementEnable 0
.
To enable the Max Power Conservation Mode, type:
racadm config -g cfgChassisPower -o cfgChassisMaxPowerConservationMode 1
To restore normal operation, type:
racadm config -g cfgChassisPower -o cfgChassisMaxPowerConservationMode 0
Enable 110 VAC PSUs:
racadm config -g cfgChassisPower -o cfgChassisAllow110VACOperation 1
Enable Server Performance Over Power Redundancy:
racadm config -g cfgChassisPower -o cfgChassisPerformanceOverRedundancy 1
Disable Server Performance Over Power Redundancy:
racadm config -g cfgChassisPower -o cfgChassisPerformanceOverRedundancy 0
To enable the power remote logging feature, type the following command:
racadm config -g cfgRemoteHosts -o cfgRhostsSyslogPowerLoggingEnabled 1
To specify the desired logging interval, type the following command:
racadm config -g cfgRemoteHosts -o cfgRhostsSyslogPowerLoggingInterval n
where n is 1-1440 minutes.
To determine if the power remote logging feature is enabled, type the following command:
racadm getconfig -g cfgRemoteHosts -o cfgRhostsSyslogPowerLoggingEnabled
To determine the power remote logging interval, type the following command:
racadm getconfig -g cfgRemoteHosts -o cfgRhostsSyslogPowerLoggingInterval
The power remote logging feature is dependent on remote syslog hosts having been previously configured.
Logging to one or more remote syslog hosts must be enabled, otherwise power consumption is logged. This can
be done either through the Web interface or the RACADM CLI. For more information, see the remote syslog
configuration instructions in the
RACADM Command Line Reference Guide for iDRAC7 and CMC
at dell.com/
support/manuals.
To enable remote power management using the Dell OpenManage Power Center, type:
racadm config -g cfgChassisPower -o cfgChassisServerBasedPowerMgmtMode 1
To restore CMC power management, type:
racadm config -g cfgChassisPower -o cfgChassisServerBasedPowerMgmtMode 0
For information about RACADM commands for chassis power, see the config, getconfig, getpbinfo, and
cfgChassisPower sections in the
RACADM Command Line Reference Guide for iDRAC7 and CMC
.
215
Vista de pagina 214
1 2 ... 210 211 212 213 214 215 216 217 218 219 220 ... 259 260

Comentarios a estos manuales

Sin comentarios