Dell Computer Drive CMC 3.2 Manual de usuario

Busca en linea o descarga Manual de usuario para Software Dell Computer Drive CMC 3.2. Dell Computer Drive CMC 3.2 User's Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 292
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente

Indice de contenidos

Pagina 1 - Reference Guide for

RACADM Command LineReference Guide foriDRAC6 1.95, iDRAC6 3.5, andCMC 3.2

Pagina 2 - Notes and Cautions

10 ContentscfgSerialHistorySize (Read/Write) . . . . . . . . 185cfgSerialCom2RedirEnable (Read/Write). . . . . 185cfgSerialSshEnable (Read/Write).

Pagina 3 - Contents

100 RACADM Subcommand DetailsOutputThe default output display shows the record number, timestamp, source, and description. The timestamp begins at mid

Pagina 4 - 4 Contents

RACADM Subcommand Details 101getversion NOTE: To use this subcommand, you must have Login privilege.Synopsisracadm getversion [-b | -c] [-m <modul

Pagina 5

102 RACADM Subcommand Details NOTE: The -b, -c and -l options are not available for CMC modules. NOTE: The -l option requires that the Lifecycle Cont

Pagina 6 - 6 Contents

RACADM Subcommand Details 103• racadm getversion -c• racadm getversion -b• racadm getversion -l -m server-1<Server> <CPLD Version> <Bla

Pagina 7

104 RACADM Subcommand Details• racadm getversion -l -m server-1 -f biosifconfig NOTE: To use this subcommand, you must have Execute Diagnostic Comman

Pagina 8 - 8 Contents

RACADM Subcommand Details 105 collisions:0 txqueuelen:1000 RX bytes:272532097 (259.9 MiB) TX bytes:0 (0.0 B)krbkeytabupload NOTE:

Pagina 9

106 RACADM Subcommand DetailskmcSelfSignedCertGen NOTE: The current release does not support this subcommand. NOTE: This is a non-extensible command

Pagina 10 - 10 Contents

RACADM Subcommand Details 107netstat NOTE: To use this subcommand, you must have Execute Diagnostic Commands permission.Synopsisracadm netstatping N

Pagina 11

108 RACADM Subcommand Detailsping6 NOTE: To use this subcommand for CMC you must have Administrator privilege for CMC and for iDRAC you must have Exe

Pagina 12 - 12 Contents

RACADM Subcommand Details 109racdump NOTE: To use this subcommand for CMC you must have Administrator privilege and for iDRAC you must have Debug per

Pagina 13

Contents 11cfgRacTuneTimezoneOffset (Read Only) . . . . . . 195cfgRacTuneLocalServerVideo (Read/Write). . . . 196cfgRacTuneLocalConfigDisable (Read/

Pagina 14 - 14 Contents

110 RACADM Subcommand DetailsSynopsisracadm racdumpExampleracadm racdump==============================================================================

Pagina 15

RACADM Subcommand Details 111System AssetTag = 00000Service Tag =Chassis Name = Dell Rack SystemChassis Location = [UNDEFINED]Power Status = ON=======

Pagina 16 - 16 Contents

112 RACADM Subcommand Details<senType> <Num> <sensorName> <status> <AC-OK status>PWR 1 PS-1 Onl

Pagina 17

RACADM Subcommand Details 113• racadm racreset hardStart the iDRAC6 hard reset sequence.racresetcfg NOTE: To use this subcommand, you must have Confi

Pagina 18 - 18 Contents

114 RACADM Subcommand Detailsremoteimage NOTE: To use this subcommand, you must have Administrator permission.Synopsisracadm remoteimage <options&

Pagina 19

RACADM Subcommand Details 115serveraction NOTE: To use this subcommand, you must have Execute Server Control Commands permission.Synopsisracadm serve

Pagina 20 - 20 Contents

116 RACADM Subcommand Detailssetassettag NOTE: To use this subcommand, you must have Administrator privilege.Synopsisracadm setassettag -m chassis &l

Pagina 21

RACADM Subcommand Details 117Table 2-31 describes the setassettag subcommand option.ExampleInput:racadm setassettag -m chassis 783839–33orracadm setas

Pagina 22 - 22 Contents

118 RACADM Subcommand Detailssetflexaddr NOTE: To use this subcommand, you must have Chassis Configuration Administrator privilege. NOTE: If the fabr

Pagina 23 - Introduction

RACADM Subcommand Details 119Example• racadm setflexaddr -i 1 0Slot 1 FlexAddress state set successfully•racadm setflexaddr -f A 1Fabric A FlexAddress

Pagina 24 - RACADM Syntax Usage

12 ContentscfgServerPowerBudgetAllocation (Read only). . 206cfgServerDNSRegisterIMC (Read/Write). . . . . 206cfgServerDNSIMCName (Read/Write) . .

Pagina 25 - RACADM Command Options

120 RACADM Subcommand DetailsTable 2-33 describes the setled subcommand options.Example for CMC• racadm setled -m server-1 -1 1LED state was set succe

Pagina 26 - Supported RACADM Subcommands

RACADM Subcommand Details 121setniccfg NOTE: To use the setniccfg command, you must have Configure iDRAC permission. NOTE: The terms NIC and Ethernet

Pagina 27

122 RACADM Subcommand Detailssetractime NOTE: To use this subcommand, you must have Administrator privilege.Synopsisracadm setractime -d <yyyymmdd

Pagina 28 - 28 Introduction

RACADM Subcommand Details 123ExampleThe setractime subcommand supports dates ranging from 1/1/1970 00:00:00 through 12/31/2030 23:59:59. To set the da

Pagina 29

124 RACADM Subcommand Detailssetslotname NOTE: To use this subcommand, you must have Administrator privilege. NOTE: See the "Editing Slot Names&

Pagina 30 - Other Documents You May Need

RACADM Subcommand Details 125Exampleracadm setslotname -i 3 mserver3The slot name was set successfully.setsysinfo NOTE: To use this subcommand, you m

Pagina 31 - Introduction 31

126 RACADM Subcommand DetailssshpkauthThis command has three mutually exclusive modes—upload, view, and delete that are determined by the options (see

Pagina 32

RACADM Subcommand Details 127Delete The delete mode allows the user to delete a key specified by the user or all keys.racadm sshpkauth -i <2 to 16&

Pagina 33

128 RACADM Subcommand Detailsssh-rsa AAAAB3NzaC1yc2EAAAABIwAAAIEAzzy+k2npnKqVEXGXIzo0sbR6JgA5YNbWs3ekoxXV fe3yJVpVc/5zrrr7XrwKbJAJTq

Pagina 34

RACADM Subcommand Details 129The sslcertdownload command returns 0 when successful and returns a nonzero number when unsuccessful.Exampleracadm sslcer

Pagina 35 - Example for racadm ?

Contents 13cfgLdapEnable (Read/Write) . . . . . . . . . . . . 217cfgLdapServer (Read/Write) . . . . . . . . . . . . 217cfgLdapPort (Read/Write) . .

Pagina 36

130 RACADM Subcommand DetailsTable 2-40 describes the sslcertupload subcommand options.The sslcertupload command returns 0 when successful and returns

Pagina 37

RACADM Subcommand Details 131sslcertview NOTE: To use this subcommand, you must have Configure iDRAC permission.Synopsisracadm sslcertview -t <typ

Pagina 38

132 RACADM Subcommand DetailsOrganization (O) : Dell Inc.Organizational Unit (OU) : Remote Access GroupCommon Name (CN) : iDRAC6 default certificateIs

Pagina 39

RACADM Subcommand Details 133sslcsrgen NOTE: To use this subcommand, you must have Configure iDRAC permission.Synopsisracadm sslcsrgen [-g] [-f <f

Pagina 40 - Examples:

134 RACADM Subcommand DetailsIf no options are specified, a CSR is generated and downloaded to the local file system as sslcsr by default. The -g opti

Pagina 41

RACADM Subcommand Details 135Table 2-43 describes the sslkeyupload subcommand options.The sslkeyupload command returns 0 when successful and returns a

Pagina 42

136 RACADM Subcommand DetailstestemailSynopsisracadm testemail -i <index>Table 2-44 provides a list and associated commands for the cfgEmailAler

Pagina 43

RACADM Subcommand Details 137Table 2-45 describes the testemail subcommand options.OutputSuccess: Test e-mail sent successfullyFailure: Unable to send

Pagina 44

138 RACADM Subcommand DetailsSubcommandstestfeature -f ad Synopsistestfeature -f ad -u <username> -p <password> [-d <diagnostic-message

Pagina 45

RACADM Subcommand Details 139• testfeature –f adkrb –u user_name@domain_nameSUCCESSFUL: User permissions are 80000fff • testfeature -f ldap -u harold

Pagina 46 - 46 RACADM Subcommand Details

14 ContentscfgChassisPowerStatus (Read Only) . . . . . . . 226cfgChassisRedundantState (Read Only) . . . . . 226cfgChassisPowerCap (Read/Write). .

Pagina 47

140 RACADM Subcommand Detailstestfeature -f ldapSynopsistestfeature -f ldap -u <username> -p <password> [-d <diagnostic-message-level&g

Pagina 48

RACADM Subcommand Details 141Synopsisracadm testtrap -i <index>Table 2-48 describes the testtrap subcommand options.traceroute NOTE: To use thi

Pagina 49

142 RACADM Subcommand Detailstraceroute6 NOTE: To use this subcommand, you must have Administrator permission. Synopsisracadm traceroute6 <IPv6 ad

Pagina 50

RACADM Subcommand Details 143The usercertupload command returns 0 when successful and returns a nonzero number when unsuccessful.Exampleracadm usercer

Pagina 51

144 RACADM Subcommand Detailsusercertview NOTE: To use this subcommand, you must have Configure iDRAC permission. NOTE: This option is applicable onl

Pagina 52 - 52 RACADM Subcommand Details

RACADM Subcommand Details 145vflashsd NOTE: To use this subcommand, you must have Access Virtual Media privilege NOTE: This option is applicable only

Pagina 53

146 RACADM Subcommand DetailsSynopsisracadm vflashpartition create <options>racadm vflashpartition delete <options>racadm vflashpartition

Pagina 54

RACADM Subcommand Details 147Examples• To create a 20MB empty partition:racadm vflashpartition create -i 1 -o drive1 -t empty -e HDD -f fat16 -s 20• T

Pagina 55

148 RACADM Subcommand Details• To delete all partitions, re-initialize the vFlash SD card:racadm vflashsd initialize• To get the status of operation o

Pagina 56

RACADM Subcommand Details 149vmdisconnect NOTE: To use this subcommand, you must have Access Virtual Media permission. NOTE: This option is applicabl

Pagina 57

Contents 15cfgIpmiLan . . . . . . . . . . . . . . . . . . . . . . . . 233cfgIpmiLanEnable (Read/Write) . . . . . . . . . . 233cfgIpmiLanPrivLimit (R

Pagina 58

150 RACADM Subcommand DetailsSynopsisracadm vmkey <action>If <action> is configured as reset, the vFlash memory is reset to the default si

Pagina 59 - RACADM Subcommand Details 59

iDRAC6 and CMC Property Database Group and Object Descriptions 151FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 60

152 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 61

iDRAC6 and CMC Property Database Group and Object Descriptions 153FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 62

154 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 63

iDRAC6 and CMC Property Database Group and Object Descriptions 155FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 64

156 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 65 - RACADM Subcommand Details 65

iDRAC6 and CMC Property Database Group and Object Descriptions 157FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 66 - 66 RACADM Subcommand Details

158 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 67

iDRAC6 and CMC Property Database Group and Object Descriptions 159FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 68 - C None Enabled

16 ContentscfgServerPeakPowerConsumptionTimestamp (Read Only) . . . . . . . . . . . . . . . . . . . . 240cfgServerPowerConsumptionClear (Write Only)

Pagina 69

160 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 70 - 70 RACADM Subcommand Details

iDRAC6 and CMC Property Database Group and Object Descriptions 161FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 71

162 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 72 - 72 RACADM Subcommand Details

iDRAC6 and CMC Property Database Group and Object Descriptions 163FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 73

164 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 74

iDRAC6 and CMC Property Database Group and Object Descriptions 165FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 75 - RACADM Subcommand Details 75

166 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 76 - 76 RACADM Subcommand Details

iDRAC6 and CMC Property Database Group and Object Descriptions 167FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 77 - RACADM Subcommand Details 77

168 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 78 - 78 RACADM Subcommand Details

iDRAC6 and CMC Property Database Group and Object Descriptions 169FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 79

Contents 17cfgServerCumulativePowerConsumptionTimeStamp(Read Only) . . . . . . . . . . . . . . . . . . . . . 251cfgServerCumulativePowerClear (Write

Pagina 80 - • racadm getmodinfo

170 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 81

iDRAC6 and CMC Property Database Group and Object Descriptions 171FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 82

172 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 83

iDRAC6 and CMC Property Database Group and Object Descriptions 173FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 84 - 84 RACADM Subcommand Details

174 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 85

iDRAC6 and CMC Property Database Group and Object Descriptions 175FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 86

176 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 87

iDRAC6 and CMC Property Database Group and Object Descriptions 177FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 88

178 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 89

iDRAC6 and CMC Property Database Group and Object Descriptions 179FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 90

18 ContentscfgIPv6Address3 (Read Only). . . . . . . . . . . 259cfgIPv6Address4 (Read Only). . . . . . . . . . . 259cfgIPv6Address5 (Read Only). .

Pagina 91

180 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 92

iDRAC6 and CMC Property Database Group and Object Descriptions 181FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 93

182 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 94

iDRAC6 and CMC Property Database Group and Object Descriptions 183FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 95

184 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 96

iDRAC6 and CMC Property Database Group and Object Descriptions 185FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 97 - RACADM Subcommand Details 97

186 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 98

iDRAC6 and CMC Property Database Group and Object Descriptions 187FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 99 - Limitations

188 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 100 - Synopsis

iDRAC6 and CMC Property Database Group and Object Descriptions 189FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 101

Contents 19cfgCurrentIPv6DNSServer1 . . . . . . . . . . . . 266cfgCurrentIPv6DNSServer2 . . . . . . . . . . . . 266cfgIPv6URL. . . . . . . . . . .

Pagina 102 - 102 RACADM Subcommand Details

190 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 103 - • racadm getversion -b

iDRAC6 and CMC Property Database Group and Object Descriptions 191FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 104

192 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 105

iDRAC6 and CMC Property Database Group and Object Descriptions 193FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 106

194 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 107

iDRAC6 and CMC Property Database Group and Object Descriptions 195FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 108 - Examples

196 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 109

iDRAC6 and CMC Property Database Group and Object Descriptions 197FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 110

198 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 111 - RACADM Subcommand Details 111

iDRAC6 and CMC Property Database Group and Object Descriptions 199FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 112

Notes and Cautions NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates potenti

Pagina 113

20 ContentscfgVFlashSD . . . . . . . . . . . . . . . . . . . . . . 275cfgVFlashSDEnable (Read/Write). . . . . . . . . 275cfgVFlashSDSize (Read Onl

Pagina 114

200 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 115

iDRAC6 and CMC Property Database Group and Object Descriptions 201FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 116 - 116 RACADM Subcommand Details

202 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 117

iDRAC6 and CMC Property Database Group and Object Descriptions 203FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 118

204 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 119 - Synopsis for CMC

iDRAC6 and CMC Property Database Group and Object Descriptions 205FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 120 - Example for iDRAC6

206 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 121

iDRAC6 and CMC Property Database Group and Object Descriptions 207FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 122

208 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 123 - (continued)

iDRAC6 and CMC Property Database Group and Object Descriptions 209FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 124 - Option Description

Contents 21cfgRacSecCsrKeySize (Read/Write) . . . . . . . . 283cfgRacSecurityData. . . . . . . . . . . . . . . . . . . 284cfgRacSecCsrIndex . . . .

Pagina 125

210 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 126

iDRAC6 and CMC Property Database Group and Object Descriptions 211FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 127

212 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 128

iDRAC6 and CMC Property Database Group and Object Descriptions 213FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 129

214 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 130

iDRAC6 and CMC Property Database Group and Object Descriptions 215FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 131 - Sample Output

216 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 132 - RACADM Subcommand Details

iDRAC6 and CMC Property Database Group and Object Descriptions 217FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 133

218 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 134

iDRAC6 and CMC Property Database Group and Object Descriptions 219FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 135

22 Contents

Pagina 136 - 136 RACADM Subcommand Details

220 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 137

iDRAC6 and CMC Property Database Group and Object Descriptions 221FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 138 - Subcommands

222 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 139

iDRAC6 and CMC Property Database Group and Object Descriptions 223FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 140

224 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 141

iDRAC6 and CMC Property Database Group and Object Descriptions 225FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 142

226 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 143

iDRAC6 and CMC Property Database Group and Object Descriptions 227FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 144

228 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 145

iDRAC6 and CMC Property Database Group and Object Descriptions 229FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 146

Introduction 231IntroductionThis document provides information about the RACADM subcommands, supported RACADM interfaces, and property database groups

Pagina 147

230 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 148

iDRAC6 and CMC Property Database Group and Object Descriptions 231FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 149

232 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 150

iDRAC6 and CMC Property Database Group and Object Descriptions 233FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 151 - Descriptions

234 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 152 - Displayable Characters

iDRAC6 and CMC Property Database Group and Object Descriptions 235FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 153

236 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 154

iDRAC6 and CMC Property Database Group and Object Descriptions 237FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 155 - FILE LOCATION:

238 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 156

iDRAC6 and CMC Property Database Group and Object Descriptions 239FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 157

24 IntroductionRACADM Syntax UsageThe following section describes the syntax usage for local, SSH/Telnet, and Remote RACADM.Local RACADMracadm getconf

Pagina 158

240 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 159

iDRAC6 and CMC Property Database Group and Object Descriptions 241FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 160

242 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 161 - Example:

iDRAC6 and CMC Property Database Group and Object Descriptions 243FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 162

244 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 163

iDRAC6 and CMC Property Database Group and Object Descriptions 245FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 164

246 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 165

iDRAC6 and CMC Property Database Group and Object Descriptions 247FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 166

248 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 167

iDRAC6 and CMC Property Database Group and Object Descriptions 249FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 168

Introduction 25RACADM Command OptionsTable 1-1 lists the options for the RACADM command.Table 1-2 provides the supported RACADM interfaces for iDRAC6

Pagina 169

250 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 170

iDRAC6 and CMC Property Database Group and Object Descriptions 251FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 171

252 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 172

iDRAC6 and CMC Property Database Group and Object Descriptions 253FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 173

254 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 174

iDRAC6 and CMC Property Database Group and Object Descriptions 255FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 175

256 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 176

iDRAC6 and CMC Property Database Group and Object Descriptions 257FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 177

258 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 178

iDRAC6 and CMC Property Database Group and Object Descriptions 259FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 179

26 Introduction NOTE: Multiple instances of remote racadm can be executed on a management station, while only one instance of local racadm can be exe

Pagina 180

260 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 181

iDRAC6 and CMC Property Database Group and Object Descriptions 261FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 182

262 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 183

iDRAC6 and CMC Property Database Group and Object Descriptions 263FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 184

264 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 185

iDRAC6 and CMC Property Database Group and Object Descriptions 265FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 186

266 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 187

iDRAC6 and CMC Property Database Group and Object Descriptions 267FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 188

268 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 189

iDRAC6 and CMC Property Database Group and Object Descriptions 269FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 190

Introduction 27deployfeaturefeaturecardfwupdategetassettaggetchassisnamegetconfiggetdcinfogetfanreqinfogetflexaddrgetioinfogetkvminfogetledgetmacaddre

Pagina 191

270 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 192

iDRAC6 and CMC Property Database Group and Object Descriptions 271FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 193

272 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 194

iDRAC6 and CMC Property Database Group and Object Descriptions 273FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 195

274 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 196

iDRAC6 and CMC Property Database Group and Object Descriptions 275FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 197

276 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 198

iDRAC6 and CMC Property Database Group and Object Descriptions 277FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 199

278 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 200

iDRAC6 and CMC Property Database Group and Object Descriptions 279FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 201

28 Introductiongetractimegetredundancymodegetselgetsensorinfogetslotnamegetssninfogetsvctaggetsysinfogettraceloggetversiongetuscversion"help"

Pagina 202

280 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 203

iDRAC6 and CMC Property Database Group and Object Descriptions 281FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 204

282 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 205

iDRAC6 and CMC Property Database Group and Object Descriptions 283FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 206

284 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 207

iDRAC6 and CMC Property Database Group and Object Descriptions 285FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 208 - Default None

286 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 209

iDRAC6 and CMC Property Database Group and Object Descriptions 287FILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 210

288 iDRAC6 and CMC Property Database Group and Object DescriptionsFILE LOCATION: C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACAD

Pagina 211

Deprecated Commands, Groups, and Objects 2894Deprecated Commands, Groups, and ObjectsThis section provides information about the deprecated RACADM sub

Pagina 212

Introduction 29racdumpracresetracresetcfgremoteimageserveractionsetassettagsetchassisnamesetflexaddrsetledsetniccfgsetractimesetslotnamesetsysinfosshp

Pagina 213

290 Deprecated Commands, Groups, and Objects• If you query a deprecated group or object, then the values are returned.• If you try to configure a depr

Pagina 214

Index 291IndexCcommunity string, SNMP, 234DDeprecated commands and objects, 289Pproperty database groupscfgActiveDirectory, 209cfgAlerting, 253cfgChas

Pagina 215

292 Indexgetled, 73getmacaddress, 74getmodinfo, 79getniccfg, 81getpbinfo, 83getpminfo, 85getraclog, 86getractime, 87getredundancymode, 88getsel, 89get

Pagina 216

Contents 3Contents1 Introduction . . . . . . . . . . . . . . . . . . . . . . . 23Supported RACADM Interfaces . . . . . . . . . . . . . 23RACADM Syn

Pagina 217

30 IntroductionOther Documents You May NeedIn addition to this guide, you can access the following guides available on the Dell Support website at del

Pagina 218

Introduction 31–The Integrated Dell Remote Access Controller 6 (iDRAC6) Enterprise for Blade Servers User Guide provides information about configuring

Pagina 219

32 Introduction• Documentation for any components you purchased separately provides information to configure and install these options.• Release notes

Pagina 220

RACADM Subcommand Details 332RACADM Subcommand DetailsThis section provides detailed descriptions of the RACADM subcommands including the syntax and v

Pagina 221

34 RACADM Subcommand DetailsThere are different escaping rules for single quoting versus double quoting.For double quoting:The following characters mu

Pagina 222

RACADM Subcommand Details 35Example for racadm ? NOTE: The following output example shows only part of the actual output for the racadm ? command. De

Pagina 223

36 RACADM Subcommand Detailsgetsysinfo -- display general CMC and system informationUsage:racadm getsysinfo [-d] [-c] [-A] [-4] [-6]------------------

Pagina 224

RACADM Subcommand Details 37arp NOTE: To use this subcommand, you must have Administrator and Execute Diagnostic Commands permission.Synopsisracadm a

Pagina 225

38 RACADM Subcommand Details NOTE: To use this subcommand, you must have Chassis Control Administrator privilege.Synopsisracadm chassisaction [-m <

Pagina 226

RACADM Subcommand Details 39clearasrscreen NOTE: To use this subcommand, you must have Clear Logs permission. Synopsisracadm clearasrscreenclosessn

Pagina 227

4 Contentsclrsel . . . . . . . . . . . . . . . . . . . . . . . . . . . 41cmcchangeover . . . . . . . . . . . . . . . . . . . . . 42config . . . .

Pagina 228

40 RACADM Subcommand DetailsTable 2-2 describes the closessn subcommand options.Examples:• racadm closessn -i 1234Closes the session 1234.•racadm clos

Pagina 229

RACADM Subcommand Details 41clrraclog NOTE: To use this subcommand, you must have Clear Logs permission. .Synopsisracadm clrraclogclrsel NOTE: To us

Pagina 230

42 RACADM Subcommand Detailscmcchangeover NOTE: To use this subcommand, you must have Administrator privilege. NOTE: This command is valid only in re

Pagina 231

RACADM Subcommand Details 43Synopsisracadm config [-c|-p] -f <filename>racadm config -g <groupName> -o <objectName> [-i <index>

Pagina 232

44 RACADM Subcommand DetailsOutputThis subcommand generates error output for any of the following reasons:• Invalid syntax, group name, object name, i

Pagina 233

RACADM Subcommand Details 45connect NOTE: You cannot use this subcommand with remote RACADM.Synopsis• racadm connect [-b] <server-n>• racadm co

Pagina 234

46 RACADM Subcommand Detailscoredump NOTE: This option is applicable only for iDRAC6. NOTE: To use this subcommand, you must have Execute Debug Comma

Pagina 235

RACADM Subcommand Details 47coredumpdelete NOTE: This option is applicable only for iDRAC6. NOTE: To use this subcommand, you must have Clear Logs or

Pagina 236

48 RACADM Subcommand DetailsSynopsis•racadm deploy -m <module> -u root -p <password> -s <ipaddress> <subnet> <gateway> -

Pagina 237

RACADM Subcommand Details 49Example• racadm deploy -m server-8 -s 192.168.0.20 255.255.255.0 192.168.0.1The server was deployed successfully. NOTE:

Pagina 238

Contents 5getniccfg . . . . . . . . . . . . . . . . . . . . . . . . . 81getpbinfo. . . . . . . . . . . . . . . . . . . . . . . . . 83getpminfo .

Pagina 239

50 RACADM Subcommand Detailsfeature NOTE: To use this subcommand to deactivate FlexAddress, you must have Chassis Configuration Administrator privile

Pagina 240

RACADM Subcommand Details 51Example• racadm feature -d -c flexaddressThe feature FlexAddress is deactivated on the chassis successfully• racadm featur

Pagina 241

52 RACADM Subcommand Detailsfeaturecard NOTE: To use this subcommand, you must have Chassis Configuration Administrator privilege.Table 2-7 lists the

Pagina 242

RACADM Subcommand Details 53Synopsisracadm featurecard -s Table 2-8 describes the featurecard subcommand option.Example$ racadm featurecard -sThe feat

Pagina 243

54 RACADM Subcommand Detailsfwupdate NOTE: To use this subcommand for CMC you must have Chassis Configuration Administrator privilege and for iDRAC y

Pagina 244

RACADM Subcommand Details 55Table 2-10 describes the firmware update method supported for each interface.Synopsis for iDRAC6racadm fwupdate -sracadm f

Pagina 245

56 RACADM Subcommand DetailsFor remote RACADM:racadm fwupdate -p -u -d <firmware image> NOTE: When using FTP, if you provide the full path to t

Pagina 246

RACADM Subcommand Details 57-g The get option instructs the firmware to get the firmware update file from the TFTP server. You must also specify the -

Pagina 247

58 RACADM Subcommand DetailsExamples for CMC• Upload the firmware image from the TFTP server and start the firmware update.racadm fwupdate -g -u -a 19

Pagina 248

RACADM Subcommand Details 59• Upload the firmware image from the FTP server and start the firmware update.racadm fwupdate -f 192.168.0.100 fred passwo

Pagina 249

6 Contentsping6 . . . . . . . . . . . . . . . . . . . . . . . . . . 108racdump . . . . . . . . . . . . . . . . . . . . . . . . 109racreset. . . .

Pagina 250

60 RACADM Subcommand Details• Query the current status of the firmware update process for a particular module.racadm fwupdate -s -m <module>• Ca

Pagina 251

RACADM Subcommand Details 61getassettag NOTE: To use this subcommand, you must have CMC Login User privilege.Synopsisracadm getassettag [-m <modul

Pagina 252

62 RACADM Subcommand DetailsExample• racadm getchassisnamePowerEdge 2955getconfigSynopsisracadm getconfig -f <filename>racadm getconfig -g <g

Pagina 253

RACADM Subcommand Details 63OutputThis subcommand generates error output upon encountering either of the following:• Invalid syntax, group name, objec

Pagina 254

64 RACADM Subcommand Details•racadm getconfig -h Displays a list of the available configuration groups on iDRAC6 in an alphabetical order.• racadm get

Pagina 255

RACADM Subcommand Details 65ExampleThe example output below is for a system with multi-slot servers.racadm getdcinfoGroup A I/O Type : Gigabit Etherne

Pagina 256

66 RACADM Subcommand Detailsgetdcinfo -ngetflexaddr NOTE: To use this subcommand, you must have CMC Login User privilege. NOTE: If FlexAddress is not

Pagina 257

RACADM Subcommand Details 67Table 2-15 describes the getflexaddr subcommand options.Example• Display current flex address settings for all slots and f

Pagina 258

68 RACADM Subcommand Detailsidrac Management Controller Disabled• Display the current flex address setting for slot 1.racadm getflexaddr -i 1Slot-1 se

Pagina 259

RACADM Subcommand Details 69getfanreqinfo NOTE: To use this subcommand, you must have CMC Login User privilege.Synopsisracadm getfanreqinfoExamplerac

Pagina 260

Contents 7testemail . . . . . . . . . . . . . . . . . . . . . . . . . 135testfeature . . . . . . . . . . . . . . . . . . . . . . . . 136testtrap . .

Pagina 261

70 RACADM Subcommand Details[Switch Module Fan Request Table]12 SLOT-12 N/A N/A Not Present N/A13 SLOT-13 N/A N/A Not Present N/A14 SLOT-14 PowerEdgeM

Pagina 262

RACADM Subcommand Details 71[Switch Module Fan Request Table]getioinfo NOTE: To use this subcommand, you must have CMC Login User privilege. NOTE: Th

Pagina 263

72 RACADM Subcommand DetailsExampleracadm getioinfogetkvminfo NOTE: To use this subcommand, you must have CMC Login User privilege.Synopsisracadm get

Pagina 264

RACADM Subcommand Details 73getled NOTE: To use this subcommand, you must have CMC Login User privilege.Synopsisracadm getled -m <module>Table

Pagina 265

74 RACADM Subcommand Detailsracadm getled -m server-9<module> <LED state>server-9 Extension(1)getmacaddress NOTE: To use this subcomman

Pagina 266

RACADM Subcommand Details 75Example• Display iSCSI MAC addresses for all servers.racadm getmacaddress -t iscsi• Display iSCSI MAC for server-1.racadm

Pagina 267

76 RACADM Subcommand Details• Display Ethernet and iSCSI MACS of all LOMs/mezzanine cards.racadm getmacaddress -aServer-3 Not Present N/A N/A N/AServe

Pagina 268

RACADM Subcommand Details 77Server-1-AGigabit EthernetPresent 00:1E:4F:2A:AF:7B00:1E:4F:2A:D3:9700:1E:4F:2A:D3:99iSCSI Present 00:1E:4F:2A:D3:9800:1E:

Pagina 269

78 RACADM Subcommand DetailsServer-6-AGigabit EthernetPresent 00:22:19:D2:1D:D4N/A N/AiSCSI Present N/A N/AServer-6-BGigabit EthernetPresent Not Insta

Pagina 270

RACADM Subcommand Details 79getmodinfo NOTE: To use this subcommand, you must have CMC Login User privilege. NOTE: The service tag field is blank for

Pagina 271

8 ContentscfgNicIPv4Enable (Read/Write). . . . . . . . . . 156cfgNicSelection (Read/Write) . . . . . . . . . . 157cfgNicVLanEnable (Read/Write) .

Pagina 272

80 RACADM Subcommand DetailsTable 2-18 describes the getmodinfo subcommand options.Example• racadm getmodinfo -m switch-1<module> <presence&

Pagina 273

RACADM Subcommand Details 81PS-2 Not Present N/A N/A N/APS-3 Present Online OKPS-4

Pagina 274

82 RACADM Subcommand DetailsSample OutputThe getniccfg subcommand displays an appropriate error message if the operation is not successful. Otherwise,

Pagina 275

RACADM Subcommand Details 83IP Address 15 = ::LOM Status:NIC Selection = DedicatedLink Detected = YesSpeed = 10Mb/sDuplex Mode

Pagina 276

84 RACADM Subcommand DetailsInput Power Allocated to Chassis Infrastructure = 51 wattsTotal Input Power Available for Allocation = 0 WStandby Input Po

Pagina 277

RACADM Subcommand Details 85getpminfo NOTE: To use this subcommand, you must have CMC Login User privilege.Synopsisracadm getpminfoExampleracadm getp

Pagina 278

86 RACADM Subcommand Details[System Power Policy Configuration]System Input Power Cap = 7928 W (7928 BTU/hr | 10%)Surplus for Peak P

Pagina 279

RACADM Subcommand Details 87 NOTE: If no options are provided, the entire log is displayed.OutputThe default output display shows the record number,

Pagina 280

88 RACADM Subcommand Details NOTE: If no options are provided, the getractime subcommand displays the time in a common readable format.Synopsisracadm

Pagina 281

RACADM Subcommand Details 89Exampleracadm getredundancymodeRedundantgetsel NOTE: To use this subcommand, you must have Login to iDRAC permission. Syn

Pagina 282

Contents 9cfgRhostsSyslogPowerLoggingEnabled . . . . . . 170cfgRhostsSyslogPowerLoggingInterval . . . . . . 170cfgUserAdmin . . . . . . . . . . . .

Pagina 283

90 RACADM Subcommand DetailsOutputThe default output display shows the record number, timestamp, severity, and description.For example:Record: 1Date/T

Pagina 284

RACADM Subcommand Details 91<senType> <Num> <sensorName> <status> <AC-OK status>PWR 1 PS-1 Online OKPWR 2 PS-2 Online OK

Pagina 285

92 RACADM Subcommand DetailsTable 2-22 describes the getslotname subcommand options.Example• racadm getslotname<Slot #> <Slot Name> <H

Pagina 286 - Default <blank>

RACADM Subcommand Details 93getssninfo NOTE: To use this subcommand, you must have Login to iDRAC permission. Based on the Session ID (SSNID) or the

Pagina 287

94 RACADM Subcommand DetailsExamples• racadm getssninfo• racadm getssninfo -A"root" "143.166.174.19" "Telnet" "NONE

Pagina 288

RACADM Subcommand Details 95getsysinfo NOTE: To use this subcommand, you must have Login to iDRAC permission. NOTE: The local racadm getsysinfo subc

Pagina 289 - Deprecated Commands, Groups

96 RACADM Subcommand DetailsLast Firmware Update = 10/26/2009 16:55:08Hardware Version = 0.01MAC Address = 00:24:e8:2e:c5:d3Comm

Pagina 290

RACADM Subcommand Details 97Current IP Address 5 = ::Current IP Address 6 = ::Current IP Address 7 = ::Current IP Address 8 = ::Current IP

Pagina 291 - Index 291

98 RACADM Subcommand DetailsNIC2 Ethernet = 00:24:e8:2e:c5:cd iSCSI = 00:24:e8:2e:c5:ceNIC3 Ethernet = 00:24:e8:2

Pagina 292

RACADM Subcommand Details 99LimitationsThe Hostname and OS Name fields in the getsysinfo output display accurate information only if Dell OpenManage S

Comentarios a estos manuales

Sin comentarios