168 iDRAC6 and CMC Property Database Group and Object Descriptions
FILE LOCATION:
C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACADM\Source\rac
DELL CONFIDENTIAL – PRELIMINARY 3/26/13 - FOR PROOF ONLY
cfgRhostsNtpMaxDist
NOTE: This object is applicable only for CMC.
cfgRhostsSyslogEnable (Read/Write)
cfgRhostsSyslogPort (Read/Write)
NOTE: For CMC, the following port numbers are reserved and cannot be used: 21,
68, 69, 123, 161, 546, 801, 4096, 5988, 5989, 6900, 9000, 60106.
Description Specifies the NTP maximum distance parameter used to aid in
NTP configuration.
Legal Values 1 – 128
Default 16
Description Enables or disables remote syslog to allow the RAC and SEL logs to
be written to up to three remote syslog servers.
Legal Values 1 (TRUE)
0 (FALSE)
Default 0
Description Remote syslog port number to use for writing the RAC and SEL
logs to a remote syslog server.
For CMC, this setting takes effect only if the
cfgRhostsSyslogEnable parameter is set to 1 (enabled).
Legal Values 10 — 65535
Default 514