138 RACADM Subcommand Details
Subcommands
testfeature -f ad
Synopsis
testfeature -f ad -u <username> -p <password> [-d
<diagnostic-message-level>]
This subcommand tests Active Directory configuration using simple
authentication (user name and password). Use the optional -d switch to
obtain additional diagnostic information, as needed.
This subcommand when executed performs the following:
Checks command syntax.
Verifies whether the required system resources are available.
Validates Active Directory configuration.
Verifies the SSL certificate and if the certificate signing request (key)
exists.
Acquires LDAP and Global Catalog Service records from DNS.
Acquires user privileges from the Active Directory server.
Checks the time to acquire user privileges with the allotted time to login.
NOTE: In the event of an error, the command displays the test that failed and all the
the tests performed earlier to the test that failed, including all the error messages.
Examples
testfeature –f ad –u user@domain –p secret
SUCCESSFUL: User permissions are xxxxxppp
NOTE: The last three digits are the user's permissions.
-d <bitmask> A bitmask (specified as a hexadecimal value) to select various
diagnostic messaging levels. This option is optional.
NOTE: -d option is not supported with the remote racadm interface.
Table 2-46. testfeature Subcommand Options
Option Description