Dell Computer Drive CMC 3.2 Manual de usuario Pagina 120

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 292
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 119
120 RACADM Subcommand Details
Table 2-33 describes the setled subcommand options.
Example for CMC
racadm setled -m server-1 -1 1
LED state was set successfully.
NOTE: The setled command generates an error when used on the extension slot of
a multi-slot server.
racadm setled -m server-9 -1 1
ERROR: Server in slot 9 is an extension of the
server in slot 1.
Example for iDRAC6
racadm setled -l 1
LED state was set successfully.
Table 2-33. setled Subcommand Options
Option Description
-m <module>
NOTE: This option is applicable for CMC only.
Specifies the module whose LED you want to configure.
<module> can be one of the following:
server-n
where
n
=1–16
switch-n
where
n
=1–6
cmc-active
chassis
-l <ledstate> Specifies whether the LED should blink.
<ledstate> can be one of the following:
0
— no blinking
1
— blinking
Vista de pagina 119
1 2 ... 115 116 117 118 119 120 121 122 123 124 125 ... 291 292

Comentarios a estos manuales

Sin comentarios