RACADM Subcommand Details 125
Example
racadm setslotname -i 3 mserver3
The slot name was set successfully.
setsysinfo
NOTE: To use this subcommand, you must have Administrator privilege.
Synopsis
racadm setsysinfo [-c chassisname|chassislocation]
<string>
Table 2-37 describes the setsysinfo subcommand options.
Example
racadm setsysinfo -c chassisname "Dell Rack System"
The chassis name was set successfully.
Subcommand Description
setsysinfo Sets the name or location of the chassis.
Table 2-37. setsysinfo Subcommand Options
Option Description
<string> Indicates a maximum of 64 non-extended ASCII chassis name
or location.
-c Sets the chassis name or location.