Vista de pagina 266
iDRAC6 and CMC Property Database Group and Object Descriptions 267
FILE LOCATION:
C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACADM\Source\rac
DELL CONFIDENTIAL – PRELIMINARY 3/26/13 - FOR PROOF ONLY
2009:123::e48f:9dd8:6f51:a669/64
# cfgCurrentIPv6Address2=
fd88:1::21e:4fff:fe1f:5371/64
# cfgCurrentIPv6Address3=
fd88:2::21e:4fff:fe1f:5371/64
# cfgCurrentIPv6Gateway=fe80::21c:23ff:fe77:6215
# cfgCurrentIPv6DNSServersFromDHCP6=1
# cfgCurrentIPv6DNSServer1=2009:123::1
# cfgCurrentIPv6DNSServer2=::
cfgIPv6URL
This group specifies properties used to configure iDRAC6 IPv6 URL.
The following sections provides information about the objects in the
cfgIPv6URL group.
cfgIPv6URLstring (Read Only)
cfgIpmiSerial
This group is applicable only for iDRAC6 and specifies properties used to
configure the IPMI serial interface of the BMC.
NOTE: The cfgIpmiSerial object group is applicable only for iDRAC6 on Rack and
Tower Servers and not for iDRAC6 Enterprise on Blade Servers or CMC.
cfgIpmiSerialBaudRate (Read/Write)
Description The iDRAC6 IPv6 URL.
Legal Values A string of up to 80 characters.
Default <blank>
Description Specifies the baud rate for a serial connection over IPMI.
Legal Values 9600, 19200, 57600, 115200
Default 57600