86 RACADM Subcommand Details
[System Power Policy Configuration]
System Input Power Cap = 7928 W (7928
BTU/hr | 10%)
Surplus for Peak Performance = 7000 W (6130
BTU/hr)
Redundancy Policy = None
Dynamic PSU Engagement Enabled = No
[Power Budgeting]
System Input Max Power Capacity = 0 W
Input Redundancy Reserve = 0 W
Input Power Allocated to Servers = 0 W
Input Power Allocated to Chassis Infrastructure = 51W
Total Input Power Available for Allocation = 0 W
Standby Input Power Capacity = 0 W
getraclog
NOTE: To use this subcommand, you must have Login to iDRAC permission.
Synopsis
racadm getraclog -i
racadm getraclog [-A] [-o] [-c count] [-s start-
record] [--more]
Table 2-19 lists the options that allow the getraclog command to read entries.
Subcommand Description
getraclog The getraclog -i command displays all the RAC log entries in the
DRAC.
Table 2-19. getraclog Subcommand Options
Option Description
-A Displays the output with no headers or labels.
-c Provides the maximum count of entries to be returned.
Vista de pagina 85