Dell Computer Drive CMC 3.2 Manual de usuario Pagina 268

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 292
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 267
268 iDRAC6 and CMC Property Database Group and Object Descriptions
FILE LOCATION:
C:\Working\ProjectDocs\Program_Releases\iDRAC6\iDRAC6_1.95_3.5\RACADM\Source\rac
DELL CONFIDENTIAL – PRELIMINARY 3/26/13 - FOR PROOF ONLY
cfgIpmiSerialConnectionMode (Read/Write)
cfgIpmiSerialChanPrivLimit (Read/Write)
cfgIpmiSerialFlowControl (Read/Write)
Description When the iDRAC6 cfgSerialConsoleEnable property is set to 0
(disabled), the iDRAC6 serial port becomes the IPMI serial port. This
property determines the IPMI defined mode of the serial port.
In Basic mode, the port uses binary data with the intent of
communicating with an application program on the serial client. In
Terminal mode, the port assumes that a dumb ASCII terminal is
connected and allows very simple commands to be entered.
Legal Values 0 (Terminal)
1 (Basic)
Default 1
Description Specifies the maximum privilege level allowed on the IPMI serial
channel.
Legal Values 2 (User)
3 (Operator)
4 (Administrator)
Default 4
Description Specifies the flow control setting for the IPMI serial port.
Legal Values 0 (None)
1 (CTS/RTS)
Default 1
Vista de pagina 267
1 2 ... 263 264 265 266 267 268 269 270 271 272 273 ... 291 292

Comentarios a estos manuales

Sin comentarios