Dell Computer Drive CMC 3.2 Manual de usuario Pagina 73

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 292
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 72
RACADM Subcommand Details 73
getled
NOTE: To use this subcommand, you must have CMC Login User privilege.
Synopsis
racadm getled -m <module>
Table 2-16 describes the getled subcommand options.
Examples
racadm getled -m server-10
<module> <LED state>
server-10 Blinking
racadm getled -m chassis
<module> <LED state>
server-10 Not blinking
racadm getled -m server-1
<module> <LED state>
server-1 ON
Subcommand Description
getled Displays the LED settings on a module: blinking, not blinking, or
unknown (for empty slots).
Table 2-16. getled Subcommand Options
Option Description
-m <module> Specifies the module whose LED settings you want to view.
<module> can be one of the following:
server-n
where
n
=1–16
switch-n
where
n
=1–6
chassis
cmc-active
Vista de pagina 72
1 2 ... 68 69 70 71 72 73 74 75 76 77 78 ... 291 292

Comentarios a estos manuales

Sin comentarios