Field Description
Enabled Select to activate the alert action.
Severity Association
Field Description
Severity The alert types available.
All Select to include all types of alerts.
Unknown Select to include unknown alerts.
Normal Select to include normal alerts.
Warning Select to include warning alerts.
Critical Select to include critical alerts.
Application Launch Configuration
Use this window to configure the application that you want to launch and to test the launch.
NOTE: Alert actions are run when a matching alert is received so the alert application launch action is a script or
batch file that does not require user interaction.
Field Description
Executable Name Specifies the fully qualified path name and file name of
the executable file that launches the application program.
Arguments Specifies or edits any required or desired command line
parameters to be used in launching the application
program. You can use the following variable substitutions
to specify information in the Arguments field:
$n = system name
$ip = IP address
$m = message
$d = date
$t = time
$sev = severity
$st = Service Tag
$e = enterprise OID
$sp = specific trap ID
$g = generic trap ID
$cn = alert category name
$sn = alert source name
$pkn = package name
$at = asset tag
Executable file: If you have an executable file (for
example, createTroubleTicket.exe), to create a trouble
ticket with parameters –arg1, -arg2, and so on; configure
the alert application launch as follows:
126