Dell OPENVIEW NNM SE 1.2 Guía para resolver problemas Pagina 104

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 156
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 103
4-42 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide
uRouteShow
Figure 4-5 shows the
uRouteShow
command, which displays the port's unicast rout-
ing information, which is the output port used to forward frames to the domain. Only
one output port is used to forward frames from one input port to a destination
domain.
The command
uRouteShow
now has three different syntax options:
uRouteShow
<port number>, <domain ID>
displays the route for port
<port #> to domain <domain ID>
uRouteShow
<port number>
displays the route for port <port #> to all the
active domains in the fabric
uRouteShow
displays the route for all the ports on the switch to all the active
domains in the fabric
In addition, in all three formats
uRouteShow
shows for each route, the domain ID of
the next hop, and the port number on the next hop.
Figure 4-5. uRouteShow Command Example
Local Domain ID: 1
In Port Domain Out Port Metric Hops Flags Next (Dom, Port
---------------------------------------------------------------------------
0 5 7 1000 1 D 5,6
6 7 2000 2 D 5,6
7 7 3000 3 D 5,6
8 7 4000 4 D 5,6
9 7 5000 5 D 5,6
1 5 5 1000 1 D 5,5
6 5 2000 2 D 5,5
7 5 3000 3 D 5,5
8 5 4000 4 D 5,5
9 5 5000 5 D 5,5
2 5 4 1000 1 D 5,4
6 4 2000 2 D 5,4
7 4 3000 3 D 5,4
8 4 4000 4 D 5,4
9 4 5000 5 D 5,4
value = 1 = 0x1
Vista de pagina 103
1 2 ... 99 100 101 102 103 104 105 106 107 108 109 ... 155 156

Comentarios a estos manuales

Sin comentarios