Dell OPENVIEW NNM SE 1.2 Guía para resolver problemas Pagina 54

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 156
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 53
3-2 Dell PowerVault 51F 8-Port Fibre Channel Switch Installation and Troubleshooting Guide
Before changing any of the factory default settings, become familiar with the opera-
tions described in this chapter including both the switchs functions and interactive
characteristics. To reset a switch to factory default values, see “Resetting Factory
Defaults” in Chapter 1.
There are several access methods for managing a switch. Table 3-1 summarizes the
different management methods.
Figure 3-1 shows the various methods and communication paths for accessing switch
management information.
NOTE: Dell recommends the switch be managed remotely using Telnet or Web man-
agement (PowerVault Switch Manager). Dell recommends the serial port be used only
to initially configure the switch and that the RS-232 serial communications cable be
removed after initial configuration.
Table 3-1. Comparison of PowerVault Switch Management Methods
Method Description Local
Out-of-band
(Ethernet)
Serial port Managed via RS-232 serial port
located on the switch
Ye s N o
Telnet commands Managed remotely using Telnet
commands
No Yes
Managing with
SNMP
Managed remotely using SNMP No Yes
PowerVault Fibre
Channel Switch
Manager
Managed remotely though Web No Yes
Vista de pagina 53
1 2 ... 49 50 51 52 53 54 55 56 57 58 59 ... 155 156

Comentarios a estos manuales

Sin comentarios