Pagina 1 - User's Guide

www.dell.com | support.dell.comDell OpenManage™Server AdministratorVersion 5.1Command Line InterfaceUser's Guide

Pagina 2 - Notes and Notices

10 Contentsomconfig Initialize Physical Disk . . . . . . . . . . . . . . . . . . . . . 168omconfig Offline Physical Disk . . . . . . . . . . . . . .

Pagina 3 - Contents

100 omconfig system assetinfo: Editing Cost of Ownership ValuesExample Commands for Adding Acquisition InformationTo provide a value for an acquisitio

Pagina 4 - 4 Contents

omconfig system assetinfo: Editing Cost of Ownership Values 101Adding Depreciation InformationDepreciation is a set of methods for computing the deval

Pagina 5

102 omconfig system assetinfo: Editing Cost of Ownership ValuesAdding Extended Warranty InformationUse the omconfig system extwarranty command to assi

Pagina 6 - 6 Contents

omconfig system assetinfo: Editing Cost of Ownership Values 103Adding Lease InformationA lease is an agreement to pay for the use of a system for a sp

Pagina 7

104 omconfig system assetinfo: Editing Cost of Ownership ValuesAdding Maintenance InformationMaintenance refers to activities required to keep the sys

Pagina 8 - 8 Contents

omconfig system assetinfo: Editing Cost of Ownership Values 105Adding Outsource InformationOutsourcing is the practice of contracting with another bus

Pagina 9

106 omconfig system assetinfo: Editing Cost of Ownership ValuesAdding Owner InformationThe owner is the party that holds legal property title to the s

Pagina 10 - 10 Contents

omconfig system assetinfo: Editing Cost of Ownership Values 107Adding Service Contract InformationA service contract is an agreement that specifies fe

Pagina 11 - Contents 11

108 omconfig system assetinfo: Editing Cost of Ownership ValuesAdding Support InformationSupport refers to technical assistance that the system user c

Pagina 12 - 12 Contents

omconfig system assetinfo: Editing Cost of Ownership Values 109Adding System InformationSystem information includes the primary user of the system, th

Pagina 13 - Introduction

Contents 11Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189Index. . . . . . . . . . . . . . . . . . . . . . .

Pagina 14 - Primary CLI Commands

110 omconfig system assetinfo: Editing Cost of Ownership ValuesExample Command for Adding Warranty InformationTo provide a value for a warranty parame

Pagina 15 - Success Messages

omreport rac: Viewing Remote Access Controller Components 111omreport rac: Viewing Remote Access Controller Components The remote access controller (R

Pagina 16 - Failure Messages

112 omreport rac: Viewing Remote Access Controller ComponentsHelp With the omreport rac CommandUse the omreport rac -? command to get a list of the av

Pagina 17 - Command Syntax Overview

omreport rac: Viewing Remote Access Controller Components 113Example Command for omreport rac authenticationWhen you type:omreport rac authentication

Pagina 18 - <n> signauth=<

114 omreport rac: Viewing Remote Access Controller Componentsomreport rac networkUse the omreport rac network command to display the NIC property valu

Pagina 19 - Example Help Commands

omreport rac: Viewing Remote Access Controller Components 115omreport rac viewcertificateUse the omreport rac viewcertificate command to view the serv

Pagina 20 - [name=value pair 2]

116 omreport rac: Viewing Remote Access Controller Components

Pagina 21

omconfig rac: Managing the Remote Access Controller 117omconfig rac: Managing the Remote Access ControllerThe omconfig rac command enables you to conf

Pagina 22

118 omconfig rac: Managing the Remote Access ControllerTable 7-1 is a high-level summary of the omconfig rac command. The column titled "Command

Pagina 23

omconfig rac: Managing the Remote Access Controller 119Help With the omconfig rac CommandUse the omconfig rac -? command to get a list of the availabl

Pagina 24

12 Contents

Pagina 25

120 omconfig rac: Managing the Remote Access ControllerExample Command for omconfig rac authenticationWhen you type:omconfig rac authentication locala

Pagina 26

omconfig rac: Managing the Remote Access Controller 121Example CommandsThe following example sets one name=value pair. Type:omconfig rac dialinusers u

Pagina 27

122 omconfig rac: Managing the Remote Access ControllerExample CommandsThe following example sets one name=value pair. Type:omconfig rac dialoutusers

Pagina 28

omconfig rac: Managing the Remote Access Controller 123Once you have generated the CSR, you can upload the certificate to the RAC using the omconfig r

Pagina 29

124 omconfig rac: Managing the Remote Access Controlleromconfig rac networkUse the omconfig rac network command to specify network parameter values. T

Pagina 30

omconfig rac: Managing the Remote Access Controller 125Example CommandThe following example sets one name=value pair. Type:omconfig rac network ippadd

Pagina 31

126 omconfig rac: Managing the Remote Access Controlleromconfig rac snmptrapsUse the omconfig rac snmptraps command to specify the SNMP trap property

Pagina 32

omconfig rac: Managing the Remote Access Controller 127omconfig rac remoteUse the omconfig rac remote command to specify the remote features property

Pagina 33

128 omconfig rac: Managing the Remote Access ControllerExample CommandThe following example sets one name=value pair. Type:omconfig rac rmdialinuser u

Pagina 34

omconfig rac: Managing the Remote Access Controller 129Example CommandThe following example sets one name=value pair. Type:omconfig rac rmsnmptrap ipa

Pagina 35

Introduction 13IntroductionWhether you are using the graphical user interface (GUI) or the command line interface (CLI), Dell OpenManage™ Server Admin

Pagina 36

130 omconfig rac: Managing the Remote Access Controlleromconfig rac usersUse the omconfig rac users command to specify user property values. Table 7-1

Pagina 37

omconfig rac: Managing the Remote Access Controller 131Example CommandThe following example sets one name=value pair. Type:omconfig rac users username

Pagina 38

132 omconfig rac: Managing the Remote Access Controller

Pagina 39 - Commands for Viewing Logs

Using the Storage Management Service 133Using the Storage Management ServiceStorage Management has a fully-featured command line interface (CLI) that

Pagina 40

134 Using the Storage Management ServiceFor example, the following omconfig command syntax for blinking a physical disk has three levels and three nam

Pagina 41

Using the Storage Management Service 135User Privileges for omreport storage and omconfig storageStorage Management requires Administrator privileges

Pagina 42

136 Using the Storage Management Serviceomreport Storage Help The following table provides the omreport storage command syntax. omreport Controller St

Pagina 43

Using the Storage Management Service 137omreport Global Information (Smart Thermal Shutdown Status)omreport Battery Status omreport Connector Status T

Pagina 44 - Example Command Output

138 Using the Storage Management Serviceomreport Enclosure Status omreport Temperature Probe Statuscontroller=idwhere id is the controller number. For

Pagina 45 - Main System Chassis

Using the Storage Management Service 139omreport Fan Statuscontroller=id enclosure=<ENCLOSUREID>info=temps index=nwhere id is the controller num

Pagina 46 - Memory Array

14 IntroductionUsing CLI Commands from Windows Command PromptsIf you are running the Windows operating system, use the 32-bit command prompt to issue

Pagina 47 - Storage Enclosures

140 Using the Storage Management Serviceomreport Power Supply Statusomreport EMM StatusTable 8-11. omreport Power Supply CommandsRequired Command Leve

Pagina 48

Using the Storage Management Service 141omreport Physical Disk Status controller=id enclosure=<ENCLOSUREID>info=emms index=nwhere id is the cont

Pagina 49 - Instrumentation Service

142 Using the Storage Management Serviceomreport Virtual Disk Status omconfig Global CommandsThe following sections provide the omconfig command synta

Pagina 50

Using the Storage Management Service 143Example SyntaxThe omconfig command syntax for enabling thermal shutdown does not require that you specify a co

Pagina 51

144 Using the Storage Management ServiceExample SyntaxThe omconfig command syntax for rescanning all controllers on the system does not require that y

Pagina 52

Using the Storage Management Service 145omconfig Rescan Controller Use the following omconfig command syntax to rescan a controller. See the online he

Pagina 53

146 Using the Storage Management Serviceomconfig Enable Controller Alarm Use the following omconfig command syntax to enable the controller alarm. See

Pagina 54

Using the Storage Management Service 147omconfig Test Controller Alarm Use the following omconfig command syntax to test the functionality of the cont

Pagina 55

148 Using the Storage Management Serviceomconfig Create Virtual Disk The online help provides additional information about creating virtual disks. The

Pagina 56

Using the Storage Management Service 149controller=id Parameter (Required) Specify the controller ID as reported by the omreport storage controller co

Pagina 57

Introduction 15Table 1-1 lists the primary CLI commands used by Server Administrator. This guide contains a section for each primary command. NOTE: O

Pagina 58

150 Using the Storage Management ServicePDISKID=<connector:enclosureID:portID | connector:targetID> Use this parameter to specify the physical d

Pagina 59

Using the Storage Management Service 151[writepolicy=<wb| wt| wc| nwc>] Parameter (Optional) Different controllers support different write polic

Pagina 60

152 Using the Storage Management ServiceExample Syntax For example, you may want to create a RAID 5 virtual disk on a PERC 3/QC controller. The online

Pagina 61

Using the Storage Management Service 153Example SyntaxFor example, to set the background initialization rate to 50 on controller 1, enter:omconfig sto

Pagina 62

154 Using the Storage Management ServiceComplete Syntax omconfig storage controller action=exportlog controller=id where id is the controller ID as re

Pagina 63

Using the Storage Management Service 155omconfig Set Patrol Read ModeUse the following omconfig command syntax to set the patrol read mode for the con

Pagina 64

156 Using the Storage Management Serviceomconfig Virtual Disk Commands The following sections provide the omconfig command syntax required to execute

Pagina 65

Using the Storage Management Service 157omconfig Blink Virtual Disk Use the following omconfig command syntax to blink the physical disks included in

Pagina 66

158 Using the Storage Management Serviceomconfig Cancel Initialize Virtual Disk Use the following omconfig command syntax to cancel the initialization

Pagina 67

Using the Storage Management Service 159omconfig Cancel Background Initialize Use the following omconfig command syntax to cancel the background initi

Pagina 68

16 IntroductionMessage:BIOS setup configured successfully.Command:omconfig system assetinfo info=depreciation duration=6Message:Asset information set

Pagina 69

160 Using the Storage Management ServiceComplete Syntax omconfig storage vdisk action=splitmirror controller=id vdisk=id where id is the controller ID

Pagina 70

Using the Storage Management Service 161To obtain the values for the controller, virtual disk, and physical disk, enter omreport storage controller to

Pagina 71

162 Using the Storage Management ServiceExample for SAS Controllers: To unassign the dedicated hot spare described in this example, enter: omconfig st

Pagina 72

Using the Storage Management Service 163Complete Syntax omconfig storage vdisk action=pausecheckconsistency controller=id vdisk=id where id is the con

Pagina 73

164 Using the Storage Management Serviceomconfig Format Virtual Disk Use the following omconfig command syntax to format a virtual disk. Complete Synt

Pagina 74

Using the Storage Management Service 165Complete Syntax omconfig storage vdisk action=changepolicy controller=id vdisk=id [readpolicy=<ra| nra| ara

Pagina 75

166 Using the Storage Management Serviceomconfig Physical Disk Commands The following sections provide the omconfig command syntax required to execute

Pagina 76

Using the Storage Management Service 167Example for SAS Controllers: To blink the physical disk described in this example, enter: omconfig storage pdi

Pagina 77

168 Using the Storage Management ServiceExample for SCSI, SATA, and ATA Controllers: To prepare to remove the physical disk described in this example,

Pagina 78

Using the Storage Management Service 169where id is the controller ID and connectorID:targetID is the connector number and physical disk number as rep

Pagina 79

Introduction 17Scripting and Comparing With the CLIThe Server Administrator CLI allows administrators to write batch programs or scripts to be execute

Pagina 80

170 Using the Storage Management ServiceTo obtain these values, you would enter omreport storage controller to display the controller IDs and then ent

Pagina 81

Using the Storage Management Service 171omconfig Unassign Global Hot Spare Use the following omconfig command syntax to unassign a physical disk as a

Pagina 82

172 Using the Storage Management ServiceExample for SCSI, SATA, and ATA Controllers: To rebuild the physical disk described in this example, enter: om

Pagina 83

Using the Storage Management Service 173where id is the controller ID. The <PDISK> variable specifies the physical disk. To obtain these values,

Pagina 84

174 Using the Storage Management ServiceComplete Syntaxomconfig storage pdisk action=cancelclear controller=id pdisk=<PDISKID>where id is the co

Pagina 85

Using the Storage Management Service 175Example Syntax For example, to recondition the battery on controller 1, enter: omconfig storage battery action

Pagina 86

176 Using the Storage Management Serviceomconfig Connector Commands The following sections provide the omconfig command syntax required to execute con

Pagina 87 - Available Alert Actions

Using the Storage Management Service 177omconfig Enable Enclosure Alarm Use the following omconfig command syntax to enable the enclosure alarm: Compl

Pagina 88

178 Using the Storage Management Serviceomconfig Disable Enclosure Alarm Use the following omconfig command syntax to disable the enclosure alarm. Com

Pagina 89 - Commands for Clearing Logs

Using the Storage Management Service 179where id is the controller ID. The <ENCLOSUREID> variable specifies the enclosure. In this syntax, <s

Pagina 90

18 IntroductionCommand level 1 is omreport, command level 2 is about, and the name=value pair is details=true.Many commands use command level 1, comma

Pagina 91

180 Using the Storage Management Serviceomconfig Set Temperature Probe Thresholds Use the following omconfig command syntax to set the minimum and max

Pagina 92

Using the Storage Management Service 181Example for SCSI, SATA, and ATA Controllers: In this example, temperature probe 3 resides in the enclosure att

Pagina 93 - Severity

182 Using the Storage Management ServiceExample Syntax For example, you may want to reset the thresholds for all temperature probes in enclosure 2 on

Pagina 94

Working With CLI Command Results 183Working With CLI Command ResultsServer Administrator Command Line Interface (CLI) users can use command output in

Pagina 95 - Example Recovery Commands

184 Working With CLI Command ResultsSave Command Results to a File That Can Be OverwrittenUse the -outc option when you want to overwrite data that is

Pagina 96 - Example Shutdown Commands

Working With CLI Command Results 185Append Command Results to an Existing FileUse the -outa option when you want to append new command results to data

Pagina 97

186 Working With CLI Command ResultsThe available formats include: • List (lst)• Semicolon-separated values (ssv)• Table (tbl)• Raw xml (xml)• Custom

Pagina 98

Working With CLI Command Results 187Table (tbl)Use the tbl or table formatting option to have your data formatted in table rows and columns. To see th

Pagina 99 - Ownership Values

188 Working With CLI Command ResultsThe example output displays as follows:<NICStatus>1</NICStatus><IPAddress>143.166.152.108</IP

Pagina 100

Glossary 189GlossaryThe following list defines or identifies technical terms, abbreviations, and acronyms used in Dell user documents.AAbbreviation fo

Pagina 101

omhelp: Getting Help With CLI Commands 19omhelp: Getting Help With CLI CommandsThe omhelp command and its equivalent, <command> -?, accesses the

Pagina 102

190 Glossaryautoexec.bat fileThe autoexec.bat file is executed when you boot your computer (after executing any commands in the config.sys file). This

Pagina 103 - Adding Lease Information

Glossary 191CAAbbreviation for certificate authority. cacheA fast storage area that keeps a copy of data or instructions for quicker data retrieval. F

Pagina 104

192 Glossaryconfig.sys fileThe config.sys file is executed when you boot your computer (before running any commands in the autoexec.bat file). This st

Pagina 105 - Adding Outsource Information

Glossary 193such as video drivers—must load when you start the program for which they were designed.DHCPAcronym for dynamic host configuration protoco

Pagina 106 - Adding Owner Information

194 Glossarynumber, and logical sectors per pack) for drives not included in the table of drive types stored in NVRAM.DTEAbbreviation for data termina

Pagina 107

Glossary 195ESMAcronym for embedded server management.expanded memoryA technique for accessing RAM above 1 MB. To enable expanded memory on your compu

Pagina 108 - Adding Support Information

196 GlossaryGBAbbreviation for gigabyte(s). A gigabyte equals 1,024 megabytes or 1,073,741,824 bytes.graphics coprocessorSee coprocessor.graphics mode

Pagina 109 - Adding Warranty Information

Glossary 197output activity; when the program sorts a list of terms, it is engaging in computational activity.IDAbbreviation for identification.IHVAcr

Pagina 110

198 Glossarykey combinationA command requiring you to press multiple keys at the same time. For example, you can reboot your computer by pressing the

Pagina 111 - Controller Components

Glossary 199MBRAbbreviation for master boot record.MCAAbbreviation for Micro Channel Architecture, which is designed for multiprocessing. MCA eliminat

Pagina 112

Notes and Notices NOTE: A NOTE indicates important information that helps you make better use of your computer. NOTICE: A NOTICE indicates either pot

Pagina 113

20 omhelp: Getting Help With CLI CommandsFigure 2-1. Different Levels of Help for a CommandYou can also parse the omconfig system assetinfo command as

Pagina 114

200 GlossarymVAbbreviation for millivolt(s).nameThe name of an object or variable is the exact string that identifies it in an SNMP Management Informa

Pagina 115

Glossary 201PCMCIAPersonal Computer Memory Card International Association. An international trade association that has developed standards for devices

Pagina 116

202 Glossaryprogram diskette setThe set of diskettes from which you can perform a complete installation of an operating system or application program.

Pagina 117 - Access Controller

Glossary 203read-only fileA read-only file is one that you are prohibited from editing or deleting. A file can have read-only status if:• Its read-onl

Pagina 118

204 GlossarySECAbbreviation for single-edge contact.serial portAn I/O port used most often to connect a modem to your computer. You can usually identi

Pagina 119

Glossary 205SRAMAbbreviation for static random-access memory. Because SRAM chips do not require continual refreshing, they are substantially faster th

Pagina 120

206 Glossarysystem.ini fileA start-up file for the Windows operating system. When you start Windows, it consults the system.ini file to determine a va

Pagina 121 - Example Commands

Glossary 207UARTAcronym for universal asynchronous receiver transmitter, the electronic circuit that makes up the serial port. UDPAcronym for user dat

Pagina 122

208 GlossaryVGA feature connectorOn some systems with a built-in VGA video adapter, a VGA feature connector allows you to add an enhancement adapter,

Pagina 123

Glossary 209VLSIAbbreviation for very-large-scale integration.VLVESAAcronym for very low voltage enterprise system architecture.vppAbbreviation for pe

Pagina 124

omreport: Viewing System Status Using the Instrumentation Service 21omreport: Viewing System Status Using the Instrumentation ServiceThe omreport comm

Pagina 126

Index 211IndexSymbols-?omconfig, 52omconfig chassis, 54omconfig rac, 119omreport, 25omreport rac, 112request for help, 19Aaboutomconfig, 53acquisition

Pagina 127

212 Index212 Indexcertificate authority, 122certificate signing request, 122change virtual disk policyomconfig, 164chassisomconfig, 54chassis fault LE

Pagina 128

Index 213controlling CLI command output, 183conventions for command parameter tables, 21core countomreport chassis processors, 35CSRabout, 122generati

Pagina 129

214 Index214 IndexFfailure messages, 16fan statusomreport, 139fancontrolomconfig chassis, 70omreport chassis, 30fansomconfig chassis, 69omreport chass

Pagina 130

Index 215omreport chassis, 34NMI button, 31Ooffline physical diskomconfig, 168omconfgcancel initialize virtual disk, 158omconfig-?, 52about, 53assign

Pagina 131

216 Index216 Indexname=value pairs, parameters, 69omconfig chassis frontpanelname=value pair, parameters, 71omconfig chassis infoname=value pair, para

Pagina 132

Index 217connector, 176controller, 144enclosure, 176globalinfo, 142pdisk, 133, 166vdisk, 156omconfig systemalertaction, 87alertlog, 19, 50, 89assetinf

Pagina 133 - CLI Command Syntax

218 Index218 Indexcore count, 35current speed, 35external clock speed, 35manufacturer, 35processor family, 35processor version, 35state, 35omreport ch

Pagina 134

Index 219prepare to remove physical disk, 167primary CLI commandomconfig, 14omhelp, 14, 19omreport, 14primary CLI commands, 14processor familyomreport

Pagina 135

22 omreport: Viewing System Status Using the Instrumentation ServiceTable 3-1 is a high-level summary of the omreport command. The column titled "

Pagina 136

220 Index220 Indexsnmpomconfig preferences, 85SNMP trap property values, 114SNMP traps, 93disabling, 92enabling, 92snmptrapsomconfig rac, 126omreport

Pagina 137

Index 221voltage warning thresholds, 83voltsomconfig chassis, 83omreport chassis, 38Wwarrantyadding, 109components, 102, 109omconfig system, 109webser

Pagina 138

222 Index222 Index

Pagina 139

omreport: Viewing System Status Using the Instrumentation Service 23frontpanel U, P, A Shows whether the front panel button settings, such as for the

Pagina 140

24 omreport: Viewing System Status Using the Instrumentation Servicealertaction U, P, A Shows warning and failure threshold values, as well as actions

Pagina 141

omreport: Viewing System Status Using the Instrumentation Service 25Help With the omreport CommandUse the omreport -? command to get a list of the ava

Pagina 142 - ° Celsius. Specifying

26 omreport: Viewing System Status Using the Instrumentation Serviceomreport chassis CommandsUse omreport chassis commands to view details for the ent

Pagina 143 - ° Celsius

omreport: Viewing System Status Using the Instrumentation Service 27Server Administrator reports values for the Redundancy Status and Redundancy Mode

Pagina 144 - Example Syntax

28 omreport: Viewing System Status Using the Instrumentation ServiceTable 3-2. BIOS Setup ParametersParameters DescriptionBezel Displays whether the b

Pagina 145 - Complete Syntax

omreport: Viewing System Status Using the Instrumentation Service 29omreport chassis bmc NOTE: This command will be phased-out in future releases. It

Pagina 146

Contents 3Contents1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13What's New for Version 5.1 . . . . . . .

Pagina 147

30 omreport: Viewing System Status Using the Instrumentation Serviceomreport chassis currentsUse the omreport chassis currents command to view current

Pagina 148

omreport: Viewing System Status Using the Instrumentation Service 31omreport chassis firmwareUse the omreport chassis firmware command to view current

Pagina 149

32 omreport: Viewing System Status Using the Instrumentation ServiceDepending on your configuration, output may resemble the following example:If you

Pagina 150 - Cache I/O cachepolicy=c

omreport: Viewing System Status Using the Instrumentation Service 33omreport chassis ledsUse the omreport chassis leds command to find out whether cle

Pagina 151

34 omreport: Viewing System Status Using the Instrumentation ServiceIf your system supports redundant memory, the redundancy output may resemble the f

Pagina 152

omreport: Viewing System Status Using the Instrumentation Service 35Connector Type refers to the type of plug or cable and plug that connects two devi

Pagina 153

36 omreport: Viewing System Status Using the Instrumentation ServiceFields Reported for Each Cache on a Particular ProcessorStatus reports whether a s

Pagina 154 - , enter:

omreport: Viewing System Status Using the Instrumentation Service 37omreport chassis pwrsuppliesUse the omreport chassis pwrsupplies command to view p

Pagina 155

38 omreport: Viewing System Status Using the Instrumentation ServiceFor each slot in the system, values display for the following fields: Index, Slot

Pagina 156

omreport: Viewing System Status Using the Instrumentation Service 39If your system has both a main system chassis and at least one direct attached sto

Pagina 157

4 Contentsomreport chassis fancontrol . . . . . . . . . . . . . . . . . . . . . . . . 30omreport chassis firmware. . . . . . . . . . . . . . . . . .

Pagina 158

40 omreport: Viewing System Status Using the Instrumentation Serviceomreport system alertactionUse the omreport system alertaction command to see a su

Pagina 159

omreport: Viewing System Status Using the Instrumentation Service 41omreport system assetinfoUse the omreport system assetinfo command to see cost of

Pagina 160

42 omreport: Viewing System Status Using the Instrumentation ServiceExample Command for Event TypeWhen you type:omreport system events type=fansThe fo

Pagina 161

omreport: Viewing System Status Using the Instrumentation Service 43The output from the omreport system pedestinations command lists each of the valid

Pagina 162

44 omreport: Viewing System Status Using the Instrumentation Serviceomreport system platformeventsUse the omreport system platformevents command to vi

Pagina 163

omreport: Viewing System Status Using the Instrumentation Service 45The system summary hardware information includes data values for installed compone

Pagina 164

46 omreport: Viewing System Status Using the Instrumentation ServiceProcessorThe following are listed for each processor in the system:• Processor man

Pagina 165

omreport: Viewing System Status Using the Instrumentation Service 47Firmware •Name •VersionNetwork Interface Card The following details are listed for

Pagina 166

48 omreport: Viewing System Status Using the Instrumentation Serviceomreport system versionUse the omreport system version command to list the version

Pagina 167

omconfig: Managing Components Using the Instrumentation Service 49omconfig: Managing Components Using the Instrumentation ServiceThe omconfig command

Pagina 168

Contents 5omconfig chassis . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54omconfig chassis biossetup . . . . . . . . . . . . . .

Pagina 169

50 omconfig: Managing Components Using the Instrumentation ServiceTable 4-1 is a high-level summary of the omconfig command. The columns titled "

Pagina 170

omconfig: Managing Components Using the Instrumentation Service 51platformevents A Determines the shutdown action, if any, to be taken for a specific

Pagina 171

52 omconfig: Managing Components Using the Instrumentation ServiceHelp With the omconfig CommandUse the omconfig -? command to get a list of the avail

Pagina 172

omconfig: Managing Components Using the Instrumentation Service 53where | more allows you to press the spacebar to see the next screen of CLI help out

Pagina 173

54 omconfig: Managing Components Using the Instrumentation Serviceomconfig chassisUse the omconfig chassis commands to default or to set values for cu

Pagina 174

omconfig: Managing Components Using the Instrumentation Service 55attribute=crab setting=enable | disable enable: Enable BIOS console redirection afte

Pagina 175

56 omconfig: Managing Components Using the Instrumentation Serviceattribute=ide setting=on | offforce=trueon: Enables this device.off: Disables this d

Pagina 176

omconfig: Managing Components Using the Instrumentation Service 57attribute=ppmode setting=at | ps2 | ecp | epp at: Set the parallel port mode to type

Pagina 177

58 omconfig: Managing Components Using the Instrumentation Serviceattribute=sataport (0...7) or (A...H)setting=off | auto off: Disables the SATA port.

Pagina 178

omconfig: Managing Components Using the Instrumentation Service 59omconfig chassis bmc NOTE: This command will be phased-out in future releases. It w

Pagina 179

6 ContentsAdding Extended Warranty Information. . . . . . . . . . . . . . . . . . . . 102Example Command for Adding Extended Warranty Information. .

Pagina 180 - ° Celsius, enter:

60 omconfig: Managing Components Using the Instrumentation ServiceThe output from the omconfig chassis bmc command lists each of the available configu

Pagina 181

omconfig: Managing Components Using the Instrumentation Service 61nicselection=nic1 | teamednic1nic2 | dracnicnic1: Enables NIC 1.teamednic1nic2: Enab

Pagina 182

62 omconfig: Managing Components Using the Instrumentation Serviceconfig=serial baudrate=9600 | 19200 | 38400 |57600 | 1152009600: Sets connection spe

Pagina 183

omconfig: Managing Components Using the Instrumentation Service 63config=serial (continued)mode=directbasic | directterminal | directbasicterminal | m

Pagina 184

64 omconfig: Managing Components Using the Instrumentation Serviceconfig=serialoverlan enable=true | false true: Enables serial over LAN for the BMC.

Pagina 185

omconfig: Managing Components Using the Instrumentation Service 65config=terminalmode deletecontrol=outputdel | outputbkspspbkspoutputdel: BMC outputs

Pagina 186 - List (lst)

66 omconfig: Managing Components Using the Instrumentation Serviceconfig=user id=numberenable=true | false id=number: ID number of the user being conf

Pagina 187 - Raw XML (xml)

omconfig: Managing Components Using the Instrumentation Service 67config=user (continued)id=user id dracusergroup=admin | poweruser | guest | testaler

Pagina 188 - Custom Delimited Format (cdv)

68 omconfig: Managing Components Using the Instrumentation Serviceomconfig chassis currentsUse the omconfig chassis currents command to set amperage p

Pagina 189 - Glossary

omconfig: Managing Components Using the Instrumentation Service 69Default Minimum and Maximum Warning ThresholdsIf you want to set both the upper and

Pagina 190

Contents 7omreport rac remote . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114omreport rac snmptraps. . . . . . . . . . . . . . . . .

Pagina 191 - Glossary 191

70 omconfig: Managing Components Using the Instrumentation ServiceYou cannot default one value and set another. In other words, if you default the min

Pagina 192

omconfig: Managing Components Using the Instrumentation Service 71omconfig chassis infoUse the omconfig chassis info command to enter an asset tag nam

Pagina 193 - Glossary 193

72 omconfig: Managing Components Using the Instrumentation ServiceAs with other commands, the CLI issues an error message if you do not have a chassis

Pagina 194

omconfig: Managing Components Using the Instrumentation Service 73omconfig chassis remoteaccess NOTE: This command is applicable to PowerEdge x8xx an

Pagina 195 - Glossary 195

74 omconfig: Managing Components Using the Instrumentation ServiceThe output from the omconfig chassis remoteaccess command lists each of the availabl

Pagina 196

omconfig: Managing Components Using the Instrumentation Service 75config=nic (continued)ipsource=static | dhcp | systemsoftware static: Static if the

Pagina 197 - Glossary 197

76 omconfig: Managing Components Using the Instrumentation Serviceconfig=nic (continued) vlanenable=true | false true: Enables the virtual LAN identif

Pagina 198

omconfig: Managing Components Using the Instrumentation Service 77config=serial (continued)mode=directbasic | directterminal | directbasicterminal | m

Pagina 199 - Glossary 199

78 omconfig: Managing Components Using the Instrumentation Serviceconfig=serialoverlan enable=true | false true: Enables serial over LAN for the BMC.

Pagina 200

omconfig: Managing Components Using the Instrumentation Service 79config=terminalmode (continued)echocontrol=enabled | disabled enabled: Enables chara

Pagina 201 - Glossary 201

8 Contentsomconfig rac rmuser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129Example Command . . . . . . . . . . . . . . . . . . . .

Pagina 202

80 omconfig: Managing Components Using the Instrumentation Serviceconfig=user id=numberenable=true | false id=number: ID number of the user being conf

Pagina 203

omconfig: Managing Components Using the Instrumentation Service 81config=user (continued)id=number lanaccesslevel=administrator | operator | user| non

Pagina 204

82 omconfig: Managing Components Using the Instrumentation Serviceomconfig chassis tempsUse the omconfig chassis temps command to set warning threshol

Pagina 205

omconfig: Managing Components Using the Instrumentation Service 83Default Minimum and Maximum Warning Thresholds NOTE: The capabilities for managing

Pagina 206

84 omconfig: Managing Components Using the Instrumentation ServiceDefault Minimum and Maximum Warning Thresholds NOTE: Systems that contain ESM3 capa

Pagina 207 - Glossary 207

omconfig: Managing Components Using the Instrumentation Service 85Therefore, for a computer named "myOmsa" running Server Administrator, the

Pagina 208

86 omconfig: Managing Components Using the Instrumentation ServiceWhen you type omconfig preferences snmp setting=rootpw, the system prompts you to su

Pagina 209 - Glossary 209

omconfig: Managing Components Using the Instrumentation Service 87omconfig systemUse the omconfig system commands to clear logs, determine how various

Pagina 210 - 210 Glossary

88 omconfig: Managing Components Using the Instrumentation ServiceComponents and Events for Which You Can Set Alert ActionsTable 4-20 lists the compon

Pagina 211 - Index 211

omconfig: Managing Components Using the Instrumentation Service 89Example Set Alert Action CommandsThe examples below are valid example commands. For

Pagina 212

Contents 9omconfig Test Controller Alarm. . . . . . . . . . . . . . . . . . . . . . 147omconfig Reset Controller Configuration. . . . . . . . . . .

Pagina 213 - Index 213

90 omconfig: Managing Components Using the Instrumentation ServiceTo clear the contents of the command log, type:omconfig system cmdlog action=clearTo

Pagina 214

omconfig: Managing Components Using the Instrumentation Service 91 Table 4-23 lists the components and the events for which you can set platform event

Pagina 215 - Index 215

92 omconfig: Managing Components Using the Instrumentation Serviceomconfig system eventsUse the omconfig system events command to enable and disable S

Pagina 216

omconfig: Managing Components Using the Instrumentation Service 93SourceAt present, source=snmptraps is a required name=value pair because SNMP is cur

Pagina 217 - Index 217

94 omconfig: Managing Components Using the Instrumentation ServiceIndexIndex refers to the number of an event for a particular component. Index is an

Pagina 218

omconfig: Managing Components Using the Instrumentation Service 95omconfig system recoveryUse the omconfig system recovery command to set the action t

Pagina 219 - Index 219

96 omconfig: Managing Components Using the Instrumentation ServiceExample Shutdown CommandsTo set the shutdown action to reboot, type:omconfig system

Pagina 220

omconfig: Managing Components Using the Instrumentation Service 97Example Thermal Shutdown CommandsTo trigger a thermal shutdown when a temperature pr

Pagina 221 - Index 221

98 omconfig: Managing Components Using the Instrumentation Service

Pagina 222 - 222 Index

omconfig system assetinfo: Editing Cost of Ownership Values 99omconfig system assetinfo: Editing Cost of Ownership Values omconfig System Asset Info O