180 Using the Storage Management Service
omconfig Set Temperature Probe Thresholds
Use the following omconfig command syntax to set the minimum and maximum warning temperature
thresholds for a specified temperature probe.
NOTE: This command is not supported on SAS controllers.
Complete Syntax
omconfig storage enclosure action=settempprobes controller=id
enclosure=<ENCLOSUREID> index=id minwarn=n maxwarn=n
where id is the controller ID and the temperature probe ID. The <ENCLOSUREID> variable specifies
the enclosure.
In this syntax, “n” is a user-specified value for the temperature in Celsius.
Example Syntax
For example, you may want to specify the minimum and maximum warning thresholds for temperature
probe 3 to 10 and 40
° Celsius.
Example for SCSI, SATA, and ATA Controllers:
In this example, temperature probe 3 resides in the enclosure attached to connector 2 on controller 1.
To set the temperature probe thresholds to 10 and 40
° Celsius, enter:
omconfig storage enclosure action=settempprobes controller=1
enclosure=2 index=3 minwarn=10 maxwarn=40
omconfig Reset Temperature Probe Thresholds
Use the following omconfig command syntax to reset the minimum and maximum warning temperature
thresholds back to their default values.
NOTE: This command is not supported on SAS controllers.
Complete Syntax
omconfig storage enclosure action=resettempprobes controller=id
enclosure=<ENCLOSUREID> index=id
where id is the controller ID and the temperature probe ID. The <ENCLOSUREID> variable specifies
the enclosure.
Example Syntax
For example, you may want to reset the thresholds for temperature probe 3 to the default values.