Dell OpenManage Server Administrator Version 5.1 Manual de usuario Pagina 167

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 222
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 166
Using the Storage Management Service 167
Example for SAS Controllers:
To blink the physical disk described in this example, enter:
omconfig storage pdisk action=blink controller=1 pdisk=0:2:0
omconfig Unblink Physical Disk
You can unblink the light (light emitting diode or LED display) on one or more physical disks attached to
a controller. Use the following omconfig command syntax to unblink one or more physical disks.
Complete Syntax
omconfig storage pdisk action=unblink controller=id pdisk=<PDISKID>
where id is the controller ID. The <PDISK> variable specifies the physical disk.
To obtain these values, enter omreport storage controller to display the controller IDs and then enter
omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.
Example Syntax
In this example, you want to unblink physical disk 0 on connector 0 of controller 1. On a SAS controller,
the physical disk resides in enclosure 2.
Example for SCSI, SATA, and ATA Controllers:
To unblink the physical disk described in this example, enter:
omconfig storage pdisk action=unblink controller=1 pdisk=0:0
Example for SAS Controllers:
To unblink the physical disk described in this example, enter:
omconfig storage pdisk action=unblink controller=1 pdisk=0:2:0
omconfig Prepare to Remove Physical Disk
Use the following omconfig command syntax to prepare a physical disk for removal:
Complete Syntax
omconfig storage pdisk action=remove controller=id pdisk=<PDISKID>
where id is the controller ID. The <PDISK> variable specifies the physical disk.
To obtain these values, enter omreport storage controller to display the controller IDs and then enter
omreport storage pdisk controller=ID to display the IDs for the physical disks attached to the controller.
Example Syntax
In this example, you want to prepare physical disk 3 on connector 0 of controller 1 for removal. On a SAS
controller, the physical disk resides in enclosure 2.
Vista de pagina 166
1 2 ... 162 163 164 165 166 167 168 169 170 171 172 ... 221 222

Comentarios a estos manuales

Sin comentarios