118
Alarm Logging and Multiple Alarm Occurrences
Table 10 Alarm Events and Reporting.
Module Alarm Event Alarm LED
Reported in
event log
Status LED
on Module
Audible
Alarm?
Fan tray More than one fan within the module
fails or hardware failure in the module
major (red) major amber yes
One fan within the module fails minor (amber) minor amber no
AC Power
Supplies
Hardware failure in a non-redundant
power configuration (3 power supplies)
major (red) major red or unlit yes
Hardware failure in a redundant power
configuration (4 power supplies)
minor (amber) minor red or unlit no
Line Card Hardware failure major (red) major amber no
Exceeds high temperature limit major (red) major unlit yes
Exceeds warning temperature limit minor (amber) minor green yes
Individual interface fails minor (amber) reported
amber
1
1. The interface’s Link LED is unlit.
no
RPM (Non-redundant Configuration with 1 RPM)
Exceeds high temperature limit major (red) major unlit yes
Exceeds warning temperature limit minor (amber) minor green no
RPM fails but CP is ok major (red) major amber yes
SFMs (Redundant Configuration with 2 SFMs)
Exceeds high temperature limit major (red) major unlit yes
Exceeds warning temperature limit minor (amber) minor green no
Any card fails minor (amber) minor amber no
Any card removed minor (amber) minor unlit no
1 SFM (Non-Redundant Configuration)
Exceeds high temperature limit major (red) major unlit yes
Exceeds warning temperature limit minor (amber) minor green no
Any card fails major (red) major amber yes
Any card removed major (red) major unlit yes
Vista de pagina 117

Comentarios a estos manuales

Sin comentarios