102 | Configuring and Using Device Groups in AWMS Dell PowerConnect W AirWave 7.1 | User Guide
4. Certain wireless access points offer proprietary settings or advanced functionality that differ from prevailing
industry standards. If you use these APs in the device group, you may wish to take advantage of this
proprietary functionality.
To configure these settings, locate the
proprietary settings areas on the Groups > Radio page and continue
with the additional steps in this procedure.
5. To configure HP ProCurve 420 set
tings exclusively, locate the HP ProCurve 420 section and adjust these
settings as required. Table 62 describes the settings and default values.
6. To configure the HP ProCurve 240, Enterasys
AP 3000 and AP 4102 Operational Mode and Max Station Data
Rate, locate the HP ProCurve 240, Enterasys AP 3000 and AP 4102 section of the Proprietary Settings area,
and define the settings. Table 63 describes the settings and default
values of this page.
7. To configure settings specific to Enterasys AP3000
and Enterasys AP4102, locate the Enterasys AP3000 and
Enterasys AP4102 section of the Proprietary Settings area, and define the settings. Table 64 describes the
settings and default values of this page.
Note: Proprietary settings are only applied to devices in the group from the specific vendor and are not configured on devices
from vendors that do not support the functionality.
Table 62 HP ProCurve 420 Fields and Default Values
Setting Default Description
Slot Time Auto Short-slot-time mechanism, if used on a pure 802.11g deployment, improves
WLAN throughput by reducing wait time for transmitter to assure clear channel
assessment.
Multicast Data Rate 5.5Mbps Sets the maximum data rate of the multicast data packets.
Rogue Scanning Enabled If enabled the 420 APs in the group will scan for rogues.
Rogue Scanning Interval (15-
100
80 min)
720 If rogue scanning is enabled, this setting controls the frequency with which
scans are conducted (in minutes). Frequent scans provide the greatest security,
but AP performance and throughput available to user devices may be impacted
modestly during a rogue scan.
NOTE: This se
tting only applies to Periodic scans.
Rogue Scanning Duration (50-
100
0 msec)
350 Specifies the amount of time, in milliseconds, the AP should spend performing
the rogue scan. If the duration is set too high users may start to experience
connectivity issues.
NOTE: This se
tting only applies to periodic scans.
Rogue Scan Type Periodic Specifies the Rogue Scanning mode. When set to Dedicated, user
s are unable to
associate to the AP.
Table 63 HP ProCurve 240, Enterasys AP 3000 and AP 4102 Fields and Default Values
Setting Default Description
Operational Mode 802.11b +
802.11g
Sets the radio operational mode for all of the ProCurve 420s, Enterasys 3000s and
4102sin the group to either b only, g only,
or b + g.
Max Station Data Rate 54 Mbps The maximum data rate at which a user can connect to the AP.